TEIs
Press ≠ to view and program the Terminal Endpoint
Identifiers (TEIs). Each TEI is supplied by your service
provider and is associated with an ISDN D-channel packet
device.
No TEIs on loop
Press ADD to program up to eight TEIs to this loop.
Sampling
Press CHANGE to select the sampling used by an S loop:
Fixed — select if two or more S-interface devices use the
•
loop and the length of the loop is less than 200 m (650 ft.).
Adaptve — select if two or more S-interface devices use
•
the loop and the length of the loop is greater than 200 m
(650 ft.), select Adaptve.
If one S-interface device is using the loop, the length of the
loop can be up to 1000 m (3,250 ft.) and the rate should be set
to Adaptve.
The BRI card must be disabled under Module status in
Maintenance programming, before you can change this
setting. You can change the setting if the card has not yet been
installed in the ICS slot.