3. LISA X - GENERAL INFORMATION
3.1 Operating requirements
It is strongly recommended that the environment, where the machine will be installed and operated, match the criteria
listed below:
Condition
Storage conditions
Space
Air humidity
Suggested air conditioning setting while the printer is in use
Optimal ambient temperature while the printer is in use
Ventilation
Air conditioner vents
Ventilation source (external door, AC)
Minimum surface area of the working room
Minimum doorway width
Minimum room height
Minimum lighting requirement
IMPORTANT!
•
The room where the printer is operated needs to be well-ventilated, with stable air temperature
and humidity; kept relatively clean, ergonomic and arranged with an efficient workflow in mind.
•
It is additionally advised that a hygrometer (air humidity sensor) be installed in the immediate
vicinity of the printer, in order to enable monitoring and control.
IMPORTANT!
•
The product should be placed on a flat, stable surface that extends beyond all edges of the product.
•
If you place the product by the wall, the distance between the product and the wall should be
greater than 50 [cm] / 20 [in].
•
The product will not work properly if it is set at an angle.
Value / Description
5-40 [°C] (41-104 [°F])
well-ventilated, with stable temperature and humidity
40-60%, non-condensing
16-25 [°C] (61-77 [°F])
22 [°C] (72 [°F])
4 complete air changes per hour minimum
not placed near the machines
not located close to the printer
3.0 [m
] / 32.29 [ft
]
2
2
0.9 [m] / 35.4 [inch]
Min 2.4 [m]
500 [lx]
Sinterit Lisa X SLS 3D Printer Original User Manual | 15