Proline Prosonic Flow I 400 Modbus RS485
Signal on alarm
Endress+Hauser
Damping
Pulse/pause ratio
Assignable measured
variables
Switch output
Switching behavior
Switching delay
Number of switching
cycles
Assignable functions
Modbus RS485
Physical interface
Terminating resistor
Depending on the interface, failure information is displayed as follows:
Current output 4 to 20 mA
4 to 20 mA
Failure mode
0 to 20 mA
Failure mode
Configurable: 0 to 999 s
1:1
• Volume flow
• Mass flow
• Sound velocity
• Flow velocity
• Electronics temperature
Binary, conductive or non-conductive
Configurable: 0 to 100 s
Unlimited
• Off
• On
• Diagnostic behavior
• Limit value
• Volume flow
• Mass flow
• Sound velocity
• Flow velocity
• Totalizer 1-3
• Electronics temperature
• Flow direction monitoring
• Status
Low flow cut off
In accordance with EIA/TIA-485-A standard
Integrated, can be activated via DIP switch on the transmitter electronics module
Choose from:
• 4 to 20 mA in accordance with NAMUR recommendation NE 43
• 4 to 20 mA in accordance with US
• Min. value: 3.59 mA
• Max. value: 22.5 mA
• Definable value between: 3.59 to 22.5 mA
• Actual value
• Last valid value
Choose from:
• Max. alarm: 22 mA
• Definable value between: 0 to 22.5 mA
Technical data
153