Coriolis mass flow measuring system
mass flow measuring system offering "low cost of ownership" as
an alternative to conventional volumetric flowmeters (40 pages)
Summary of Contents for Endress+Hauser Proline Promass 80 HART Series
Page 1
Safety Instructions Proline Promass 80 HART ATEX II2GD & II1/2GD; IECEx Zone 1, Zone 21, Zone 0/1 Dokument: XA00097D Sicherheitshinweise für elektrische Betriebsmittel für explosionsgefährdete Bereiche gemäß Richtlinie 94/9/EG (ATEX) und IEC 60079-0 ä 5 Document: XA00097D Safety instructions for electrical apparatus for explosion-hazardous areas according to Directive 94/9/EC (ATEX) and IEC 60079-0 ä...
Page 2
Amennyiben nem tudja elolvasni ezt az útmutatót, akkor Pojasnilo glede potrdila o skladnosti EU megrendelheti az Ön anyanyelvére lefordítva is. Proizvajalec Endress+Hauser s to izjavo o skladnosti in navedbo oznake CE izjavlja, da je ta izdelek skladen s predpisanimi evropskimi smernicami. EK-megfelelőségi nyilatkozat Upoštevane smernice, standardi in dokumenti so navedeni v izjavi o skladnosti.
Page 3
Proline Promass 80 XA00097D EG-Konformitätserklärung / EC declaration of conformity / Déclaration CE de conformitè A0009286 Endress+Hauser...
Page 4
Acetylen, Schwefelkohlenstoff, Wasserstoff / Acetylene, carbon disulphide, hydrogen / Acétylène, hydrogène, sulfure de carbone 0.02 Temperaturklasse / Temperature class / Classe de température EN /IEC Maximale Oberflächentemperatur / 450 °C 300 °C 200°C 135°C 100°C 85°C Maximum surface temperature / 842 °F 572°F 392°F 275°F 212°F 185°F Température maximale de surface A0016202 Endress+Hauser...
Sicherheitshinweise Proline Promass 80 HART ATEX II2GD & II1/2GD; IECEx Zone 1, Zone 21, Zone 0/1 Dieses Dokument ist ein fester Bestandteil der folgenden Betriebsanleitung: • BA00057D, Proline Promass 80 HART Inhaltsverzeichnis Allgemeine Warnhinweise ..............6 Besondere Bedingungen .
Stromkreisen der Zündschutzart Kategorie "ib" mit der Explosionsgruppe IIC bzw. IIB, ändert sich die Zündschutzart in Ex ib IIC bzw. Ex ib IIB. Eigensichere Stromkreise der Zünd- schutzart Kategorie "ib" sind für Bereiche geeignet, welche Kategorie 2 Betriebsmittel erfordern. Endress+Hauser...
ä 10 Beschreibung Messsystem Die Messsystem besteht aus Messumformer und Messaufnehmer. Zwei Ausführungen sind verfügbar: • Kompaktausführung: Messumformer und Messaufnehmer bilden eine mechanische Einheit. • Getrenntausführung: Messumformer und Messaufnehmer werden räumlich getrennt montiert und über ein Verbindungskabel miteinander verbunden. Endress+Hauser...
IEC/EN 60079-0. 29 Durchflussrichtung Ga beschreibt das Schutzniveau für den Einbau in Zone 0, Gb für den Einbau in Zone 1, Da für den Ein- bau in Zone 20 und Db für den Einbau in Zone 21. Endress+Hauser...
Page 10
Ein-/Ausgänge (Pos.-Nr. 18 im Typenschlüssel) Zündschutzart A, D, 8 nicht eigensichere Ausgänge S, T Ex ia Hinweis! Eine genaue Erläuterung zu diesen Werten, bez. der verfügbaren Aus- und Eingänge, sowie eine Beschreibung der zugehörigen Klemmenbelegungen und Anschlusswerte: ä 16. Endress+Hauser...
Page 13
Der Messumformer der Getrenntausführung besitzt die Temperaturklasse T6 bei Einbau in das Ex d-Gehäuse bis zu einer Umgebungstemperatur von T = 60 °C. Der maximale Umgebungstemperaturbereich beträgt –20…+60 °C. Optional ist eine Ausführung für eine Umgebungstemperatur T bis –40 °C verfügbar. Endress+Hauser...
Klemmennummern: 4/5 = grau; 6/7 = grün; 8 = gelb; 9/10 = rosa; 11/12 = weiß; 41/42 = braun Klemmenbelegung und Anschlusswerte Die Verbindung der Getrenntausführung, zwischen Messaufnehmer und Messumformer, wird in der Zündschutzart Ex i ausgeführt. " Achtung! Es dürfen nur vom Endress+Hauser vorkonfektionierte und gelieferte Verbindungskabel verwendet werden. Endress+Hauser...
Versorgungsspannung Schutzleiter Funktionale Werte AC: U = 85…260 V; AC: U = 20…55 V Achtung! DC: U = 16…62 V Beachten Sie die Erdungs- konzepte der Anlage! Leistungsaufnahme: 15 VA / 15 W Eigensicherer Stromkreis nein 260 V AC Endress+Hauser...
Statuseingang galvanisch getrennt, 3…30 V DC = 5 k Servicestecker Der Servicestecker dient ausschließlich zum Anschluss von Endress+Hauser freigegebenen Service-Interfaces. Warnung! Der Servicestecker darf nicht nicht bei explosionsfähiger Atmosphäre angeschlossen werden. Gerätesicherung Warnung! Verwenden Sie nur die folgenden Sicherungstypen, welche auf der Netzteilplatine montiert sind: •...
Page 19
Safety Instructions Proline Promass 80 HART ATEX II2GD & II1/2GD; IECEx Zone 1, Zone 21, Zone 0/1 This document is an integral part of the following Operating Instructions: • BA00057D, Proline Promass 80 HART Contents General warnings ..............22 Special conditions .
Page 20
ATEX II2GD & II1/2GD; IECEx Zone 1, Zone 21, Zone 0/1 Proline Promass 80 Endress+Hauser...
Page 21
Proline Promass 80 ATEX II2GD & II1/2GD; IECEx Zone 1, Zone 21, Zone 0/1 Endress+Hauser...
• If Category "ia" intrinsically safe circuits of the measuring device are connected to certified intrinsically safe Category "ib" circuits with explosion group IIC or IIB ratings, the type of protection changes to Ex ib IIC or Ex ib IIB, as applicable. Intrinsically safe "ib" circuits are suitable for areas which require Category 2 equipment. Endress+Hauser...
The measuring system consists of transmitters and sensors. Two versions are available: • Compact version: transmitters and sensors form a mechanical unit. system • Remote version: transmitters and sensors are separated by open ground when installed and connected to each other via a connecting cable. Endress+Hauser...
29 Direction of flow protection level according to IEC/EN 60079-0, Ga describes the protection level for installations in zone 0, Gb for installations in zone 1, Da for installations in zone 20 and Db for installations in zone 21 Endress+Hauser...
8 to 10 Process connection, seal for sensor M 11 Certificates 12 Calibration 13 Approvals 14 Housing 15 Type of cable entry 16 Low temperature version, power supply, keyboard/display 17 Software 18 Inputs/outputs 19… Extended order code Endress+Hauser...
Page 26
A, D, 8 non-intrisically safe outputs S, T Ex ia Note! For a detailed explanation of these values, regarding the available outputs and inputs, as well as a description of the associated terminal assignments and connection data: ä 32 onwards. Endress+Hauser...
Page 29
The remote version transmitter has a T6 temperature class rating when installed in the Ex d housing for ope- ration at ambient temperatures up to T = 60 °C. The maximum ambient temperature range is –20 to +60 °C. A version for ambient temperatures T up to –20 °C is optionally available. Endress+Hauser...
Transmitter housing on connection housing, remote version Sensor connection housing, remote version Screw terminal for connecting to the potential equalization Connection compartment cover Connecting cable remote version m and n see following section "Cable entries" Note! Connection of remote version connecting cable ä 31 Endress+Hauser...
Terminal No.: 4/5 = gray; 6/7 = green; 8 = yellow; 9/10 = pink; 11/12 = white; 41/42 = brown Terminal assignment and connection data The connection of the remote version, between the sensor and the transmitter, has Ex i explosion protection. " Caution! Only preterminated connecting cables supplied by Endress+Hauser may be used. Endress+Hauser...
AC: U = 85 to 260 V; AC: U = 20 to 55 V Caution! DC: U = 16 to 62 V Observe the grounding concepts of the system! Power consumption: 15 VA / 15 W Intrinsically safe circuit 260 V AC Endress+Hauser...
24 (+) 25 (–) 26 (+) 27 (–) "Inputs/outputs" Pulse/ Current output – – frequency output HART Pulse/ Current output Status input Relay output frequency output HART Pulse/ Current output 1 Status input Current output 2 frequency output HART Endress+Hauser...
3 to 30 V DC = 5 k Service adapter The service adapter is only used for connecting service interfaces approved by Endress+Hauser. Warning! It is not permissible to connect the service adapter whilst the atmosphere is considered to be explosive.
Page 35
Conseils de sécurite Proline Promass 80 HART ATEX II2GD & II1/2GD; IECEx Zone 1, Zone 21, Zone 0/1 Le présent document fait partie intégrante du manuel de mise en service suivant: • BA00057D, Proline Promass 80 HART Sommaire Avertissements généraux..............36 Conditions particulières.
à sécurité intrinsèque certifiés de la catégorie "ib" avec le groupe d'explosion IIC ou IIB, le mode de protec- tion antidéflagrant est modifié en Ex ib IIC ou Ex ib IIB. Les circuits à sécurité intrinsèque de la catégorie "ib" sont appropriés pour les zones qui requièrent des composants de catégorie 2. Endress+Hauser...
Le système de mesure se compose du transmetteur et du capteur. Deux versions sont disponibles : • Version compacte : le transmetteur et le capteur constituent une entité mécanique. mesure • Version séparée : le transmetteur et le capteur sont montés séparément et reliés par un câble de liaison. Endress+Hauser...
CEI/EN 660079-0. Ga décrit le niveau de protection pour le montage en zone 0, Gb pour le montage en zone 1, Da pour le montage en zone 20 et Db pour le montage en zone 21 Endress+Hauser...
Version haute pression 8…10 Raccord process, joint capteur M 11 Certificats 12 Etalonnage 13 Agréments 14 Boîtier 15 Type d'entrée de câble 16 Variante version basse temp., alimentation, cla- vier, affichage 17 Software 18 Entrées/sorties 19… Référence de commande étendue Endress+Hauser...
Page 40
A, D, 8 sorties sans sécurité intrinsèque S, T Ex ia Remarque ! Vous trouverez une explication précise concernant ces valeurs, ou concernant les entrées/sorties disponibles, ainsi qu'une description des affectations des bornes et des valeurs de raccordement correspondantes: ä 46. Endress+Hauser...
Page 43
En cas de montage dans un boîtier Ex d, le transmetteur de la version séparée possède la classe de température T6 jusqu'à une température ambiante de T = 60 °C. La gamme de température ambiante maximale est de –20…+60 °C. Une version pour une température ambiante T jusqu'à –40 °C est disponible en option. Endress+Hauser...
Borne à visser pour le raccordement à la compensation de potentiel Couvercle du compartiment de raccordement Câble de liaison version séparée m et n voir chapitre suivant "Entrées de câble" Remarque ! Connexion câble de raccordement version séparée ä 45 Endress+Hauser...
Affectation des bornes et valeurs de raccordement La liaison entre capteur et transmetteur pour la version séparée est réalisée en mode de protection Ex i. " Attention ! Seuls les câbles de raccordement préconfectionnés et livrés par Endress+Hauser doivent être utilisés. Endress+Hauser...
Attention ! AC : U = 20…55 V Respectez les concepts DC : U = 16…62 V de mise à la terre de l'installation ! Consommation : 15 VA / 15 W Circuit à sécurité intrinsèque 260 V AC Endress+Hauser...
3…30 V DC = 5 k Le connecteur de service sert exclusivement au raccordement d'interfaces de service validées par Connecteur de service Endress+Hauser. Danger ! Le connecteur de service ne doit pas être raccordé en présence d'une atmosphère explosible. Fusibles de l'appareil Danger ! Utilisez exclusivement les types de fusibles suivants, qui sont montés sur la platine alimentation :...
Need help?
Do you have a question about the Proline Promass 80 HART Series and is the answer not in the manual?