Connecting via an NS-series PT
Overview
An online connection from the CX-Programmer through an NS-series PT to a PLC connected to the PT is
possible.
CX-Programmer
System Configuration
The CX-Programmer can be connected through an NS-series PT to a PLC across two network layers.
CX-Programmer
1. Connection between
computer and PT
1. Connection between computer and PT
USB
Ethernet
Controller Link
Serial
Modem
2. Connection between PT and PLC
Ethernet
Controller Link
Serial
Note:
Note:
CX-Server Runtime_Page 32
USB, Ethernet, or
Controller Link connection
Ladder programs and other data can be uploaded and downloaded.
NS-series PT (See note 1.)
2. Connection
between PT
and PLC
Connection method
Connection method
1:N NT Link
1:1 NT Link
Host Link
Memory Link
Note 1:
When connecting an NSJ Controller to a computer or PLC, always use the serial port or
Ethernet port on the Display Section. The above connection method is not possible if the NSJ
Controller is connected to an Expansion Unit or serial port on the Controller Section.
Note 2:
If you connect the PT to PLC 1 using a serial connection, you will not be able to connect online
to PLC 2 or PLC 3 across the network layers.
The CX-Integrator cannot be used if the computer is connected to the PLC through a PT.
Screen display refresh speed and touch panel response may be slower when the CX-
Programmer is connected through a PT.
NS-series PT
Serial, Ethernet, or
Controller Link connection
PLC 1
Network layers
crossed: 1 layer
PLC 1
Yes
Yes
Yes
No
No
No
PLC
PLC 2
PLC 3
Network layers
crossed: 2 layers
Connection
Yes
Yes
Yes
No
No
Connection
PLC 2
PLC 3
Yes
Yes
Yes
Yes
No
No
(See note 2.)
(See note 2.)
No
No
No
No
No
No