Omron CX-PROGRAMMER V9 Operation Manual page 114

Table of Contents

Advertisement

OMRON
Section/Rung Manager
CX-Programmer allows all six functions described above to be done from the Section/Rung Manager dialog
for sections and commented rungs of the programs.
Use the following procedure to edit the section and rung comments on the Section/Rung Manager dialog.
1, 2, 3...
By selecting Section/Rung Manager from the Program Menu, the rung comment data can be read (imported)
from the project in the personal computer, and operations can be performed to move the data up and down (CX-
Programmer Ver. 4.0 or later). This function allows rung comments to be allocated to a program all at once after
uploading the program under the following conditions, even if there is no comment file (COMMENTS.CMT) in
the Memory Card/EM file memory.
(b) Instead of using the Edit commands, it is possible to drag and drop the section in a
similar way to moving it. However, if the 'Ctrl' key is held down before dropping
the section (on the program item), then a copy operation will take place.
5. Replacing a program section
(a) To replace a section, copy or move the required section on top of the one to be
replaced. A confirmation is then requested.
6. Deleting a program section
(a) Select the section to be deleted, and from the Edit menu select Delete.
1.
Select the Section/Rung Manager button from the toolbar.
2.
Select the program to be edited from the Program field.
3.
All sections in the selected program are displayed on the Section field. The rung
numbers and the rung comments of the selected section are displayed on the Rung
Comment field.
4.
Use the buttons on the right to edit rungs (i.e. Insert, Cut, Copy, Paste, and Delete). To
edit the rung comment, select the rung and press the Edit Comment button.
5.
Change the rung comment using the Edit Rung Comment dialog. Press the Enter key to
close the dialog and to reflect the changes. To create a new paragraph, use the key
combination Ctrl+Enter.
6.
Select the section/s and use the buttons on the right of the dialog to edit them (i.e. Insert,
Cut, Copy, Paste, and Delete). To edit the section name and/or comments, press the
Rename button.
7.
Change the section name and/or the comment using the Rename Section dialog. Press
the Enter key to close the dialog and to reflect the changes. To create a new paragraph,
use the key combination Ctrl+Enter.