Omron CX-PROGRAMMER V9 Operation Manual page 356

Table of Contents

Advertisement

OMRON
Setting Node Address 02
Node address 02 is set in the same way as node address 01.
Receive area from remote nodes
Setting Node Address 03 (Setting an Offset)
For node address 03, the procedure for setting the node refresh sequence and the offset is as follows:
1
Select node address 03 from the node address list on the left.
2
With node address 03, the node refresh sequence does not match the default, so the order of addresses must be
changed. Change the node refresh sequence by either clicking F4: Move Up Area or F5: Move Down Area in
the Function Bar, or pressing the F4 or F5 function keys.
3
Double-click on the Offset cell, and input the data size to be offset. In this example, set the offset size to 10
words.
With this setting, 20 words sent from node 01 will be received, starting from CIO 1000, and with an offset of 10
words (i.e., CIO 1010 to CIO 1030).
Local node send area
F5: Move Down Area
PART 2: CX-Server PLC Tools
CHAPTER 10 – Data Links
CX-Server PLC Tools_ Page 113