Omron CQM1 Operation Manual page 190

Sysmac cqm1h/cqm1 series dedicated i/o units
Hide thumbs Also See for CQM1:
Table of Contents

Advertisement

Specifications
E3C-MA11
Item
Sensing distance
Minimum sensing object
Standard sensing object
Directional angle
Differential distance
Ambient
Incandes-
operating
cent lamp
illumination
Sunlight
Ambient operating tempera-
ture
Ambient operating humidity
Vibration resistance
Shock resistance
Enclosure rating
Item
Sensing distance
Minimum sensing mark (black mark on
white paper)
Ambient operating
Incandescent
illumination
lamp
Sunlight
Ambient operating temperature
Ambient operating humidity
Vibration resistance
Shock resistance
Enclosure rating
Thru-beam model
E3C-S10
E3C-1
10 cm
1 m
2-mm non-
4-mm non-
transparent
transparent
object
object
---
10 to 60
3 to 20
---
3,000 lux max. on the surface of each sensing object
10,000 lux max. on the surface of each sensing object
–25 to 70 C with no icing
35% to 85%
10 to 55 Hz, 1.5-mm double amplitude in X,
Y, and Z directions for 2 hours each
2
500 m/s
3 times each in X, Y, and Z directions
IEC IP64
IEC IP66 (water resistive)
(drip proof)
E3C-VS1G
1
0.2 cm
0.9 mm at the
center of the
sensing distance
1,000 lux max. on the surface of each sensing object.
3,000 lux max. on the surface of each sensing object
–10 to 70 C with no icing
35% to 85%
10 to 55 Hz, 1.5-mm double amplitude in X, Y, and Z directions for 2 hours each
2
500 m/s
IEC IP64 (drip proof)
Diffuse
reflective
model
E3C-2
E3C-DS5W
2 m
5 cm
8-mm non-
---
transparent
object
10
10 cm
white paper
3 to 15
---
20% max.
10 to 500 Hz,
1.5-mm dou-
ble ampli-
tude in X, Y,
and Z direc-
tions for 2
hours each
IEC IP50
Reflective model for mark detection
E3C-VS3R
E3C-VM35R
3
0.5 cm
3.5
1.6 mm at the
0.2 mm at the
center of the
center of the
sensing distance
sensing distance
–25 to 70 C with
no icing
IEC IP50 (drip proof)
Appendix A
Limited reflective model
E3C-DS10
E3C-LS3R
10 cm
3
0.3 cm
5
5 cm
1
1 cm
white paper
white paper
10% max.
3% max.
1,000 lux
max.
3,000 lux
max.
10 to 55 Hz, 1.5-mm double
amplitude in X, Y, and Z
directions for 2 hours each
IEC IP64 (drip proof)
E3C-VS7R
0.5 cm
7
1.0 cm
0.6 mm at the
center of the
sensing distance
–10 to 70 C with
no icing
171