Sensitivity Adjustment
Teaching with a Sensing Object
1,2,3...
5-2-2
E2C-MA11 Proximity Sensor Module
Teaching without a Sensing Object
1,2,3...
Teaching with a Sensing Object
1,2,3...
1. Place the sensor head in the sensing range of the sensor.
2. Connect the CQM1-TU001 to the CQM1-SEN01.
3. Set the module selector to the number of the sensor module on which
teaching will be performed, and the set the mode selector of the sensor
module to RUN.
4. Set the mode setting selector of the CQM1-TU001 to SET.
5. Place the object at the sensing position and press the teaching button. The
teaching indicator will turn red.
6. Move the object and press the teaching button. If teaching is successful,
the teaching indicator will turn from red to green. If teaching is unsuccess-
ful, the teaching indicator (red) will flash, in which case change the position
of the object and the sensing distance that have been set and repeat from
step 5.
7. Set the mode selector to RUN to complete the sensitivity setting on the
E3X-MA11.
Note
1. Be sure to perform teaching before use.
2. When the CQM1-TU001 is connected to a sensor unit, operations on the
CQM1-TU001 precede operations on sensor modules.
1. Place the sensor head in the sensing range of the sensor.
2. Connect the CQM1-TU001 to the CQM1-SEN01.
3. Set the module selector to the number of the sensor module on which
teaching will be performed.
4. Set the mode setting selector of the CQM1-TU001 to SET.
5. Press the teaching button. The teaching indicator (red) will be lit.
6. Set the mode selector to RUN to complete the sensitivity setting on the
E2C-MA11. If teaching is unsuccessful, the teaching indicator will flash. In
this case make sure that the optical fiber cable of the sensor is connected
securely and that there is no sensing object, and then repeat from step 5.
1. Place the sensor head in the sensing range of the sensor.
2. Connect the CQM1-TU001 to the CQM1-SEN01.
3. Set the module selector to the number of the sensor module on which
teaching will be performed.
4. Set the mode setting selector of the CQM1-TU001 to SET.
5. Place the object at the sensing position at which the desired output will be
OFF and press the teaching button. The teaching indicator will turn red.
6. Move the object to the position where you want to turn ON the output and
press the teaching button. If teaching is successful, the teaching indicator
will turn from red to green.
7. Set the mode selector to RUN to complete the sensitivity setting on the
E3X-MA11. If teaching is unsuccessful, the teaching indicator (red) will
flash, in which case make sure that the sensor cable is connected, change
the position of the object and the sensing distance that have been set, and
repeat from step 5.