403.xxx
Warning [403.xxx] Check CT SB2 switch box wiring: CTA OUTPUT, TAPS XN and/or X1 may be
disconnected.
Reason:
Solution:
404.xxx
Warning [404.xxx] Check CT SB2 switch box wiring: CTA PRIM and/or PRIM IN terminal may be
disconnected.
Reason:
Solution:
405.xxx
Warning [405.xxx] Check CT SB2 switch box wiring: CTA SEC terminal, TAPS XN IN and/or X1 IN
may be disconnected.
Reason:
Solution:
406.xxx
Warning [406.xxx] Check CT SB2 switch box wiring: <text depending on connection actually
detected>
Reason:
Solution:
407.xxx
Warning [407.xxx] Check CT SB2 switch box wiring: Wrong polarity at CTA SEC or CTA OUTPUT
terminal
Reason:
Solution:
408.xxx
Warning [408.xxx] Check CT SB2 switch box wiring: <text depending on missing connection
actually detected>
Reason:
Solution:
409.xxx
Warning [409.xxx] Check CT SB2 switch box wiring: <text depending on incorrect connection
actually detected>
Reason:
Solution:
411.xxx
Warning [411.xxx] Firmware download to switch box failed! Error: SBErrNo
Reason:
Solution:
415.xxx
Warning [415.xxx] Quick measurement cannot be started. Please disconnect the CT SB2 switch
box.
Reason:
Solution:
OMICRON
The CTA OUTPUT sockets of the CT SB2 are not properly connected to the CT Analyzer
output.
Make sure that the CTA OUTPUT sockets on the CT SB2 are properly connected to the
CT Analyzer and restart your test.
The CTA PRIM sockets of the CT SB2 are not properly connected to CT Analyzer input
PRIM.
Make sure that the CTA PRIM sockets on the CT SB2 are properly connected to
CT Analyzer input PRIM and restart your test.
The CTA SEC sockets of the CT SB2 are not properly connected to CT Analyzer input
SEC.
Make sure that the CTA SEC sockets on the CT SB2 are properly connected to
CT Analyzer input SEC and restart your test.
The CTA SEC sockets of the CT SB2 are not properly connected to CT Analyzer input
SEC.
Make sure that the CTA SEC sockets on the CT SB2 are properly connected to
CT Analyzer input SEC and restart your test.
Reverse polarity at the CTA SEC sockets or the CTA OUTPUT sockets of the CT SB2.
Make sure that the CTA SEC sockets and the CTA OUTPUT sockets on the CT SB2 are
properly connected to CT Analyzer and restart your test.
At least one of the CT taps enabled for multi-ratio testing is not connected to the CT SB2
correctly.
Make sure that all CT taps are connected correctly to the TAPS terminals on the CT SB2
and restart your test.
Wiring of at least two CT taps is mixed, e.g. CT tap X2 is connected to TAPS X3 on the
CT SB2 and vice versa.
Make sure that all CT taps are connected to the correct TAPS terminals on the CT SB2
and restart your test.
CT SB2 firmware download failed.
Ensure that the CT SB2 is connected to the CT Analyzer and repeat the firmware
download to the CT SB2.
You are trying to initiate a Quick measurement with the CT SB2 switch box still connected
to the CT Analyzer.
Measurements using Quick Test are not possible when the CT SB2 is connected to the
CT Analyzer. Remove all connections to the CT SB2 and restart your Quick measurement
on the CT Analyzer.
Error and warning messages