Table 8-28: Parameters assessed for IEC 60044-1 protection CTs (continued)
Param.
Description
Kx
Dimensioning factor (according to
IEC 60044-1 class PX).
Ie
Accuracy limiting secondary excitation
current.
Ie1
Max. allowed secondary excitation current
at E
.
1
Rct
Secondary winding resistance.
Rprim
Primary winding resistance.
Table 8-29: Parameters assessed for IEC 60044-1 metering CTs
Param.
Description
Class
Accuracy class according to standard.
Δϕ
Phase deviation.
ε
Current ratio error.
FSi
Instrument security factor (indirect meas. method).
Rprim
Primary winding resistance.
132
Parameter assessed for IEC 60044-1
protection CTs
standard classes
5P 10P 5PR 10PR PX 2P, 3P,
x
x
x
x
x
x
OMICRON
extension
2PR, 3PR,
4P, 6P
4PR, 6PR
x
x
x
x
x
x
x
x
Parameter assessed
for IEC 60044-1
metering CTs
0.1, 0.2, 0.2s,
3, 5
0.5, 0.5s, 1
x
x
x
x
x
x
x
x
x
OMICRON