Omicron CT SB2 User Manual page 158

Ct analyzer
Hide thumbs Also See for CT SB2:
Table of Contents

Advertisement

CT Analyzer User Manual
The following values are displayed in the Results CT Ratio card:
Table 10-8: Values displayed for CT Ratio measurement type
Value
Description
OUTPUT
Internally measured RMS current value and phase of the output signal.
SEC
RMS value of the voltage measured at input SEC.
This input is considered as the phase reference, therefore the phase is always 0.
PRIM
RMS value and phase of the voltage measured at input PRIM.
N
Current ratio of the CT calculated from the voltages measured at inputs SEC and PRIM.
f
Frequency measured at input SEC.
Use the following wiring for CT ratio measurement (example):
Figure 10-10: Wiring example for CT ratio measurement
156
OMICRON

Advertisement

Table of Contents
loading

Table of Contents