Tally Connections; Serial Port Connections; Table 2-1: Serial Control Pin Definitions - Rs-232 Dce Configuration - evertz 8010-SIE Instruction Manual

Digital source id encoders
Table of Contents

Advertisement

2.1.4. Tally Connections

FAULT TALLY OUT:
open circuit when the 8010-SIE is processing video normally. The output will be grounded
when the optional SDI bypass relay is active.

2.1.5. Serial Port Connections

SERIAL: A 9 pin female 'D' connector for connection to the RS-232/RS-422 serial communications.
See section 5.2.2 for the information on configuring the port for various applications.
On the 8010-SIE this port is configured at the factory for configured for a 'straight through RS-232
connection to a PC COM port. In this configuration it can be used for uploading firmware to the unit or
connected to a Profile server (when the 8010-Sie is in LVS-SID mode). Table 2-1 shows the pinout of
the serial port in its default RS-232 DCE configuration.
Pin

Table 2-1: Serial Control Pin Definitions - RS-232 DCE Configuration

On the 8010-SIE this port can also be configured in an RS-422 controller port and used to sense status
information from the video recorder supplying video to the 8010-SIE (when the 8010-SIE is in VTR SID
mode). ). Table 2-2 shows the pinout of the serial port in its RS-422 Controller configuration.
INSTALLATION
A BNC connector for output of a SMPTE 269M fault tally. The output will be
Name
#
1
GND
Chassis ground
2
TxD
RS-232 Transmit Output
3
RxD
RS-232 Receive Input
4
5
Sig Gnd
RS-232 Signal Ground
6
7
RTS
RS-232 RTS Input
8
CTS
RS-232 CTS Output
9
Model 8010-SIE Digital Source ID Encoder Manual
Description
Revision 2.2
Page 2-2