3.5.3. Setting the Generator Time

When the 8010-Sie is operating in the TIME SID mode, the user can set the generator time using the
following procedure. Press the DISPLAY key one or more times to display the generator time if it is not
already displayed. The display prompt will show GTM when generator time is being displayed. The
ENTER and CLEAR keys are used in conjunction with the numeric keys to set the generator time.
Press the ENTER key to recall the last time that you entered into the generator. The display prompt at
the left of the display will blink while data entry mode is active, and the dual functioned keys are now
changed to their numeric values. If you want to re-enter this time press the ENTER key to complete the
data entry into the generator time
.
Pressing any numeric key will clear the previous value and place the new value into the numeric
display, starting at the right. Unentered digits are assumed to be zero, hence leading zero digits are
not required. When the required number of digits are entered, then press the ENTER key to complete
the data entry into the generator time.
Attempts to enter too many digits, or make illegal entries, i.e. 65 minutes, will result in the display
returning to the last valid time entry made. Re-enter the correct value and press the ENTER key.
Pressing the CLEAR key will cancel the data entry mode without changing any data.
The numeric keys return to their normal display functions when the data entry has been completed by
pressing ENTER or cancelled by pressing the CLEAR key. The display prompt will return to its steady
On state when data entry mode has been completed.
Numeric entry mode must be terminated (GTM will be On steady) before any of the
front panel keys will resume normal operation.
In TIME SID mode, press GEN HOLD key (when the Generator time is being displayed on the front
panel) to start or stop the generator clock. In all the other operating modes, the generator time will be
slaved to incoming code from the GPS antenna, LTC or VITC reader or VTR timecode.

3.5.4. Turning the VITC Generator On

The VITC GEN ON/OFF key is used to turn the VITC keyer on and off. (You must exit the Setup menu
to turn the VITC generator on or off.) When the VITC generator is Off, the program video passes
through the VITC keyer with nothing added. When the VITC generator is On, the VITC will be added to
the program video.