Model 8010-SIE Digital Source ID Encoder Manual
The leftmost digits of the display will blink and indicate
TIME ZONE
. The last time zone you entered
will be shown as
+/-HH:MM
where HH represents the whole hour time offset and MM indicates the
minutes offset for time zones where there are partial hours. The +/- sign indicates if the time is ahead
or behind UTC. If you want to re-enter this time zone offset, press ENTER. To change the whole hour
offset press the
or
keys. To change the partial hour offset press the
or
keys. The
8010-SIE-GPS II will only allow valid time zone offsets to be selected. If daylight saving time is
observed in your area, then you should enter the time zone offset for standard time. You can set up
the daylight saving time adjustment using the procedure outlined in section 3.8.5.
When you have selected the correct time zone offset, press the ENTER key to complete the data entry
process. The arrow keys return to their normal functions when the data entry has been completed by
pressing the ENTER key or canceled by pressing the CLEAR key. The display prompt will stop
blinking when data entry mode has been completed.
OPERATION
Page 3-31