The power entry module combines a standard IEC 320 power inlet connector, voltage selector switch,
two 5 x 20 mm fuse holders (one active, one spare) and an EMI line filter.
To change the mains voltage setting, open the cover of the power entry module using a small
screwdriver. Remove the drum selector switch, and re-insert it so that the desired voltage is visible
through the opening on the mains connector cover. Check that the correct fuse is in use as shown in
section below.

2.3.1.2. Changing the Fuse

The fuse holder is located inside the power entry module. To change the fuse, open the cover of the
power entry module using a small screwdriver. The fuse holder on the bottom contains the active fuse.
The one at the top contains a spare fuse. Pull the bottom fuse holder out and place a fuse of the
correct value in it. Use slo blo (time delay) 5 x 20 mm fuses rated for 250 Volts with the following
current ratings:
For 115 Volt operation
For 230 Volt operation
Make sure that the arrow is pointing down when you replace the fuse holder. Close the door on the
power entry module and connect the mains voltage.
Never replace with a fuse of greater value.

2.3.2. Power Requirements

– Model 8010-SIE-GPS II and Later Versions of Model 8010-SIE

2.3.2.1. Selecting the Correct Mains Voltage

Power requirements are 115 or 230 volts AC at 50 or 60 Hz. The 8010-SIE-GPS II and later versions of
the 8010-SIE have a universal power supply that automatically senses the input voltage. Power should
be applied by connecting a 3-wire grounding type power supply cord to the power entry module on the
rear panel. The power cord should be minimum 18 AWG wire size; type SVT marked VW-1, maximum
2.5 m in length.
The power entry module combines a standard power inlet connector, two 5 x 20 mm fuse holders and
an EMI line filter.

2.3.2.2. Changing the Fuse

The fuse holder is located inside the power entry module. To change the fuses, disconnect the line
cord from the power entry module and pull out the fuse holder from the power entry module using a
small screwdriver. The fuse holder contains two fuses, one for the line and one for the neutral side of
the mains connection. Pull out the blown fuse and place a fuse of the correct value in its place. Use