This manual addendum provides supplementary information to the 8084/8084AD/8085 manual revision
1.3, published in March 2002. It describes new features applicable to the Evertz 8084, 8084AD and
8085 Closed Caption Encoders with firmware revision R020527 or later.
1.
OVERVIEW
Ability to set the clock time, date, time zone and DST observance from the front panel
Ability for the encoder to automatically perform Daylight Saving Time changes in April and October
Improved Time of Day/Time Zone Packet encoding to ensure interoperability with consumer VCRs
Improved Content Advisory Packet encoding to ensure packets are inserted when upstream
bandwidth is all used up.
Fixed bug with encoding and detection of Time Zone Packet for time zone 6
Fixed bug with synchronizing the clock to MetaCast for the month of July
Added Auto padding of Network Name Packet to 4 characters to aid in Auto Clock function on
Panasonic VCRs.
"0-based" indexing for 8085 EIA-708 caption translator (8085 firmware version R020618)
2.
SETTING THE ENCODER CLOCK
A new menu item SET UTC CLOCK appears in the Engineering Menu of the encoders. This menu item
allows the user to set the internal real time clock directly from the front panel. Note that the time and
date entered are the UTC time. Setting of the clock is done in four stages.
Setting the UTC time
Setting the UTC date
Setting the local time zone offset from UTC
Setting whether Daylight Saving time is observed in the local region.
!
When you press the
stage to the next, or press the SETUP key at any time during the process to exit the clock setting
function and return to the original clock settings.
2.1.
Setting the Time
When you enter the time setting stage, the front panel display shows the current UTC time of the
internal clock with the Hours digits blinking, indicating that they can be changed. E.g. Time = 04:06:53.
Press the " or # keys to change the hours digits or press the ! key move to the minutes or the $ key
to move to the seconds. Set the minutes and seconds the same way. When you have entered the
correct UTC time press the SELECT key to move to the date setting stage.
2.2.
Setting the Date
When you enter the date setting stage, the front panel display shows the current UTC date of the
internal clock with the Month blinking, indicating that it can be changed. E.g. June 04, 2002 Tue. Press
the " or # keys to change the month or press the ! key to move to the day of the month or the $ key
to move to the year. Set the day and year the same way. As you change the month, day or year, the
day of the week will automatically change. When you have entered the correct UTC date press the
SELECT key to move to the time zone setting stage.
Date of Issue: July 26, 2002
Model 8084, 8084AD and 8085 Closed Caption Encoders
key you will be prompted to set the time.
Copyright Evertz Microsystems Ltd. All rights reserved
Manual Change Sheet 1.3-1
Press the SELECT key to move from one
Page 1 of 6

Advertisement

loading

Summary of Contents for evertz 8084

  • Page 1 Manual Change Sheet 1.3-1 This manual addendum provides supplementary information to the 8084/8084AD/8085 manual revision 1.3, published in March 2002. It describes new features applicable to the Evertz 8084, 8084AD and 8085 Closed Caption Encoders with firmware revision R020527 or later.
  • Page 2: Daylight Saving Time Adjustment

    Model 8084, 8084AD and 8085 Closed Caption Encoders Manual Change Sheet 1.3-1 2.3. Setting the Time Zone When you enter the time zone setting stage the front panel display shows the local time zone offset from UTC. E.g. Time zone = 05. The number shown is the number or hours between the standard time in the local time zone and UTC.
  • Page 3 Day packet. The Time Zone packet must be inserted locally at each affiliate in order to encode the correct time zone offset for the region. See application note AN3 at the back of the 8084 manual for more information about encoding time in XDS packets.
  • Page 4 Model 8084, 8084AD and 8085 Closed Caption Encoders Manual Change Sheet 1.3-1 4.1. Notes about Panasonic and Quasar VCRs The Matsushita chipset (used in Panasonic and Quasar VCRs) has some anomalies in the way they handle Time of Day and Time Zone XDS packets •...
  • Page 5 METACAST2 SYNCINC BUG FIXED As of Firmware revision R020726 the 8084 will return the month of July as the string “JUL” to satisfy the requirements of MetaCast2. Previous versions returned the month as “JLY” which caused MetaCast to return the error MetaCast failed to synchronize to the encoder.
  • Page 6 Model 8084, 8084AD and 8085 Closed Caption Encoders Manual Change Sheet 1.3-1 NETWORK NAME PADDED TO 4 CHARACTERS Panasonic VCRs require that the network name XDS packet contain either the string “<sp>PBS” or “PBS<sp>” where <sp> is the space character.

This manual is also suitable for:

8084ad8085