Power Connections; Changing The Fuses; Mounting - evertz 3480DEC18-MP2SD-ASI18 User Manual

High density mpeg-2 sd decoder
Table of Contents

Advertisement

3480DEC18-MP2SD-ASI18
High Density MPEG-2 SD Decoder
2.3.

POWER CONNECTIONS

The 3480DEC18-MP2SD-ASI18 has two universal power supplies (main and backup) that operate on
either 100-115 or 220-240 volts AC at 50 or 60 Hz and automatically sense the input voltage. Power
should be applied by connecting a 3-wire grounding type power supply cord to the power entry modules
on the rear panel.

2.3.1. Changing the Fuses

Check that the line fuse is rated for the correct value marked on the rear panel.
Never replace with a fuse of greater value.
The fuse holder is located inside the power entry module. To change the fuses, pull out the fuse holder
from the power entry module using a small screwdriver. The fuse holder contains two fuses, one for
the line and one for the neutral side of the mains connection. Pull out the blown fuse and place a fuse
of the correct value in its place. If the fuse blows, replace with a fuse of the correct type only in this
case T3.15AL250V; Use of any higher amperage value will void the warranty.
NOTE: Fuses are for your protection. Never substitute a fuse of a higher rating, or
bypass it.
NOTE: The fuse will not blow unless the unit is overstressed. Before replacing the
fuse, correct the condition that caused it to fail.
2.4.

MOUNTING

To successfully install the 3480DEC18-MP2SD-ASI18:
1. Unused IP address on the network or a DHCP server
2. Serial cable
3. VLPro Server IP address
The 3480DEC18-MP2SD-ASI18 is equipped with rack mounting angles and fits into a standard 19 inch
by 1 ¾ inch rack space.
Page 4