Lcd Display; Main Display - Smartgen HGM9510N User Manual

Paralleled genset controller
Table of Contents

Advertisement

NOTE: Regarding ECU genset, in Stop/Auto mode, Press
and ECU power output are active.).
CAUTION: Factory default password is "00318", and users can change it in case others change the advanced
parameter settings. Please clearly remember the password after changing. If you forget it, please contact SmartGen
services and send the PD information in the controller page of "ABOUT" to the service personnel.

4.3 LCD DISPLAY

4.3.1

MAIN DISPLAY

Paging is applied for the main screen;
Main Screen includes the following contents:
Gen: voltage, frequency, current, active power, reactive power;
Bus: voltage, frequency;
Engine: speed, temperature, engine oil pressure, battery voltage;
Part of status displays.
Status page includes the following contents:
Genset status, and ATS status.
Engine page includes the following contents:
Engine speed, engine temperature, engine oil pressure, fuel level, configurable analog 1, configurable
analog 2, battery voltage, charger voltage, accumulated running time, accumulated start times.
NOTE: If CAN BUS is connected and engine information is read from J1939, this page also includes: coolant pressure,
coolant level, fuel temperature, fuel pressure, inlet temperature, exhaust temperature, turbo pressure, fuel consumption,
total fuel consumption and so on. (Different engines have different parameters.)
Generator page includes the following contents:
Phase voltage, wire voltage, frequency, phase sequence, current, active power of different phases, total
active power and percentage, reactive power of different phases, total reactive power and percentage,
apparent power of different phases, total apparent power, power factor of different phases, average
power factor, accumulated electric power, total power of multi-genset; ground current and percentage,
unbalanced current and percentage, unbalanced voltage and percentage, voltage harmonic parameter.
NOTE:
HGM9510N/HGM9530N Paralleled Genset Controller User Manual
is used for page scroll and
NOTE:
P stands for active power;
Q stands for reactive power.
Fig. 2 Power Factor Display Description
button and it shall power on the ECU (fuel output
for screen scroll.
Page 14 of 116

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hgm9530n

Table of Contents