Smartgen HGM9510N User Manual page 87

Paralleled genset controller
Table of Contents

Advertisement

No.
Type
24
Reset Maintenance
25
Reserved
26
Aux. High Temp
27
Aux. Low OP
28
Remote Start (On Load)
29
Remote Start (Off Load)
30
Manual Start
Remote Start
31
(On Demand)
32
Reserved
33
Simulate Stop key
34
Simulate Manual key
35
Reserved
36
Simulate Auto key
37
Simulate Start key
38
Simulate Gen C/O key
39
Simulate Mains C/O key
40
NEL Manual Trip
NEL Manual
41
Re-connection
Power
Management
42
Mode
43
Mains Parallel Mode
44
First Priority
45-
Reserved
46
47
Alternative Config 1
48
Alternative Config 2
49
Alternative Config 3
50
Balance Test
51
Speed Raise
HGM9510N/HGM9530N Paralleled Genset Controller User Manual
Controller will set maintenance time and date as default when input is
active.
Connected sensor digital input.
Connected sensor digital input.
In Auto mode, when input active, genset can be started and with load
after genset is OK; when input inactive, genset will stop automatically.
In Auto mode, when input active, genset can be started and without
load after genset is OK; when input inactive, genset will stop
automatically.
In Auto mode, when input active, genset will start automatically; when
input inactive, genset will stop automatically
In Auto mode, when input active, all genset that need to be paralleled
will start according to the priority and calling other generator
according to the load.
An external button (Not Self-locking) can be connected and pressed
as simulate panel.
An external button (Not Self-locking) can be connected and pressed
as simulate panel.
This is simulate G-close key.
This is simulate G-open key.
An external button (Not Self-locking) can be connected. Details of
function description please see the following.
Power management mode will be displayed on the LCD when the
input is active. In this mode, the controller will control genset
synchronize, power sharing, scheduled start, scheduled stop,
generator closed, generator opened but genset start or stop.
Details of function description please see the following.
The genset will output constant power and not share load with other
units when the input is active.
It is the highest priority when the input is active. Used for
main/standby genset selection.
The alternative configuration is active when the input is active. Users
can set different parameters to make it easy to select current
configuration via input port.
Description
Page 87 of 116