Nice HySecurity SlideSmart DC Series Installation And Programming Manual page 70

Slide gate operator
Table of Contents

Advertisement

Table 10. Smart DC Controller - Installer Menu Functions
Ref.
User Menu
No.
Display
LT 3 (75 SECS)
LOITERING ALERT
36
SA 0 (OFF)
STC ADDRESS
37
ELD 0 (RUN MODE)
EXIT LOOP SET
38
70
70
support.hysecurity.com
Setting Options
(Bold = Factory
Menu Tasks and Explanations
Settings)
This function monitors activation
of the Outside Obstruction Loop
when there is no activation of
0 = 0 seconds
the gate. When the adjustable
period of time is exceeded, User
1 = 15 seconds
Relay No. 13 triggers and reports
2 = 45 seconds
loitering in the diagnostics log.
Adjust the time delay before
3 = 75 seconds
activating the user relay. Maximum
time setting is 135 seconds. See
4 = 105 seconds
Setting the User Relay Function in
5 = 135 seconds
the Installer Menu
NOTE: This menu controls a user
relay set to Function No. 13
Set system address for network
communication:
0 = No network
0 = no network communication
1 to 99 Network
"drop" address
1 - 99 sets individual polling
addresses.
0 = Run mode
1 = Show
Controls Hy5A or Hy5B Free
frequency
Exit detector. If an Hy5B is used,
2 = Show call
additional settings of 4-8 are
level 0-7
available.
3 = Set
Frequency
DISPLAY AND MENU OPTIONS
DC Controller
Display
Connections
User relays
RS-485
Hy5B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HySecurity SlideSmart DC Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents