If required, adjust the sensitivity using menu
option in the installer menu with the default being
A for Automatic:
• A = Automatic
• M = Motorcycle
• 0 = Low with boost (See NOTE.)
• 1 = Normal with boost (See NOTE.)
• 2 = High with boost (See NOTE.)
• 3 = X-High with boost (See NOTE.)
• 4 = Low without boost
• 5 = Normal without boost
• 6 = High without boost
• 7 = X-High without boost
Display
Outside Obstruction loop detector
OR 1
function
Inside Obstruction loop detector
IR 1
function
DL 1
Vehicle detector logic
78
78
support.hysecurity.com
Table 12. Vehicle Detector - Configurable Functions
Meaning
NOTICE
Refer to the the Hy5B instructions for all the options
available for each individual Hy5B installed.
SMART DC CONTROLLER
NOTICE
A boost feature is applied for settings 0 through
3. Boost increases the sensitivity during a call
and is useful for maintaining continuous
detection if the signal becomes weak (such as
with tractor-trailer trucks). Sensitivity settings
4 through 7 are the same as 0 through 3, but
without the boost feature.
9. Vehicle detector functions are configurable
through the Installer Menu as described in
Table 12.
Installer Menu Setting Options
(Bold - Default)
0 = Pause closing only
1 = Enable reverse to open.
0 = Pause closing only
1 = Enable reverse to open.
1 = Standard (Close Timer does not begin
counting until all loops have cleared)
2 = Quick close (Close Timer can count to zero,
even while loops are active, so the gate will close
as soon as the loops are clear)
3 = Forced time out (Close Timer is forced to
zero when both the OOLD & IOLD are tripped
simultaneously. Additionally, all other close inputs
are memorized and the gate closes immediately
when all open commands and vehicle detector
inputs are clear.
4 = Full Anti-tailgate (In addition to the functions
of 3, the gate stops during the opening cycle when
both OOLD & IOLD are tripped simultaneously.
When the OOLD and IOLD loops are cleared, the
gate closes immediately.