Nice HySecurity SlideSmart DC Series Installation And Programming Manual page 78

Slide gate operator
Table of Contents

Advertisement

If required, adjust the sensitivity using menu
option in the installer menu with the default being
A for Automatic:
• A = Automatic
• M = Motorcycle
• 0 = Low with boost (See NOTE.)
• 1 = Normal with boost (See NOTE.)
• 2 = High with boost (See NOTE.)
• 3 = X-High with boost (See NOTE.)
• 4 = Low without boost
• 5 = Normal without boost
• 6 = High without boost
• 7 = X-High without boost
Display
Outside Obstruction loop detector
OR 1
function
Inside Obstruction loop detector
IR 1
function
DL 1
Vehicle detector logic
78
78
support.hysecurity.com
Table 12. Vehicle Detector - Configurable Functions
Meaning
NOTICE
Refer to the the Hy5B instructions for all the options
available for each individual Hy5B installed.
SMART DC CONTROLLER
NOTICE
A boost feature is applied for settings 0 through
3. Boost increases the sensitivity during a call
and is useful for maintaining continuous
detection if the signal becomes weak (such as
with tractor-trailer trucks). Sensitivity settings
4 through 7 are the same as 0 through 3, but
without the boost feature.
9. Vehicle detector functions are configurable
through the Installer Menu as described in
Table 12.
Installer Menu Setting Options
(Bold - Default)
0 = Pause closing only
1 = Enable reverse to open.
0 = Pause closing only
1 = Enable reverse to open.
1 = Standard (Close Timer does not begin
counting until all loops have cleared)
2 = Quick close (Close Timer can count to zero,
even while loops are active, so the gate will close
as soon as the loops are clear)
3 = Forced time out (Close Timer is forced to
zero when both the OOLD & IOLD are tripped
simultaneously. Additionally, all other close inputs
are memorized and the gate closes immediately
when all open commands and vehicle detector
inputs are clear.
4 = Full Anti-tailgate (In addition to the functions
of 3, the gate stops during the opening cycle when
both OOLD & IOLD are tripped simultaneously.
When the OOLD and IOLD loops are cleared, the
gate closes immediately.