Menu Setting
AP 0 AC LOSS
UPS FAIL OPEN
RT 0 (60 SECS)
AP1 AC LOSS
MAXIMUM RUN TIMER
UPS FAIL CLOSE
AP 2 AC LOSS
AUTO OPEN
AP 3 AC LOSS
NO CLOSE TIMER
50
50
support.hysecurity.com
Table 8. AC Power Loss Menu
Normal gate functions continue until system detects battery voltage drop
below 21V. DEAD BATTERY appears on display and gate automatically opens.
Any pushbutton CLOSE command will close gate and any OPEN command
will re-open gate. If battery continues to diminish and system detects 18V
or less, system initiates an automatic open cycle. Any new open or close
command is ignored and LCD appears blank. System remains in this disabled
state until reset or battery recovers to 24V.
Normal gate functions continue until system detects a battery voltage
drop below 21V. DEAD BATTERY appears on display and gate
automatically closes. Gate can be opened by a special sequence of a
STOP input followed by an OPEN push-button or directly opened with
Fire Department Open command. Any push-button CLOSE command
closes gate. If battery continues to diminish and system detects 18V or
less, system initiates an automatic open cycle if not already on a limit. Any
new open or close command is ignored and LCD appears blank. System
remains in this disabled state until reset or battery recovers to 24V.
Operator automatically opens gate five seconds after AC power loss
detected. Gate remains open until AC power is restored. Any push-button
CLOSE command will close gate and any open command will open
gate. When battery voltage drops below 21V or less, system initiates an
automatic open cycle. Gate will remain open until battery recovers to 24V.
Operator initially does nothing after it detects AC power loss until
it receives an open command. Once an open command is received,
operator opens and remains in that state. Any push-button CLOSE
command will close gate and any open command will open gate. When
battery voltage drops below 21V or less, system initiates an automatic
open cycle. Gate will remain open until battery recovers to 24V.
DISPLAY AND MENU OPTIONS
Description
Need help?
Do you have a question about the HySecurity SlideSmart DC Series and is the answer not in the manual?
Questions and answers