Protection Sensors List
The following sensors have been tested with Nice | HySecurity gate operators by an
independent laboratory and certifi ed to comply with UL 325 7th Edition. Select sensors from this
325
list for UL compliant gate automation solutions. Contact the sensor manufacturer for specifi c
recommendations for use.
Nice | HySecurity Recommended Sensors
Mfg. Part # or
Model
E3K-R10K4-NR-1
Photo Eyes
NIR-50-325
(Retro
-refl ective)
IRB-RET
E-931-S50RRGQ
Blue Bus
Photo Eyes
Era Photo Eyes
(Thru-Beam)
OVS-50TNR
IRB-MON
E-960-D90GQ
Sentir Series
Edge
Sensors
CPT210-2U-#-T2
Hy2NC (Converts 10K
Edge Sensor
to NC Monitoring)
Converters
GEM103 (Converts 10K
to Pulsed Monitoring)
Edge
iGAZE RE Kit
Wireless
Kits
WEL-200
Multi-Input
Module
The Solution – MIM-62
Installers must assess each specifi c site and
UL 325 Standard:
• The operator shall monitor for the presence of every device at least once during each open and close cycle (32.1.8)
install sensors that protect all potential entrapment zones.
• It shall not be possible to make simple modifi cations in the fi eld by adding, suppressing or changing, either on the operator or external
entrapment protection device(s), to bypass, interfere with, or otherwise defeat the monitoring function. (32.1.10)
For more information visit Safety or see latest operator manuals at
• Entrapment zones are now defi ned for each gate type (4.23, 4.24, 4.29, 4.34)
Slide Gates: To enable fully automatic operation, all SLIDE gate operators will require a minimum of TWO monitored external
entrapment protection sensors (one for each direction) to protect entrapment zones in both the open and close direction of travel.
Preferred solution for slide gates: A photo eye for the close direction and a hard-wired edge sensor for the open direction that
Slide Gate
is mounted to the face of the leading post of the fence behind the gate. (Reach through injuries are the most common hazard
associated with automatic sliding gates)
Common
Swing Gates: To enable fully automatic operation, all SWING gate operators will require a minimum of ONE monitored external
Entrapment
entrapment protection sensor to protect entrapment zones in either the open or close direction of travel. However, an additional
monitored sensor is required if there is a risk of entrapment in both directions of gate travel.
Zones
Preferred solution for swing gates: A photo eye for the close direction and/or a hard-wired wraparound edge sensor on the leading
A
Trailing End
edge of the gate, which protects for both directions of gate travel.
A
Indicates Additional Potential Entrapment Zone
Nice |
Brand
Hysecurity
Part #
Omron
MX000999
EMX
-
EMX
-
Seco-Larm
-
EPMB/A
EPMOB/A
EPLOB/A
Nice |
EPMAB/A
HySecurity
EMBORB/A
Optex
-
EMX
MX3990
Seco-Larm
-
"AS1502-*
ASO Safety
AS1501-*"
Miller Edge
-
HySecurity
MX4018
Miller Edge
-
Transmitter
Solutions
-
EMX
-
Miller Edge
-
support.hysecurity.com
SAFETY REQUIREMENTS
Control Boards
Max
Smart
Smart
SmartCNX
Range
Touch
DC
40 ft
•
•
•
45 ft
•
•
•
53 ft
•
•
•
46 ft
•
•
•
45 ft
•
33 ft
•
•
65 ft
•
•
•
90 ft
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Install Edge for
Draw-in Zone
1
Protects open direction
(EDGE OPEN)
hysecurity.com | 800-321-9947
2
Leading End
SECURE
Mercury
1050
310
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PUBLIC
1 of 2
Page
Install Photo eye
Protects Leading End
(EYE CLOSE)