Display
Alert, Error or
Condition
S m a r t
C o n t r o l l e r i s
No display, LED
receiving power,
blinking
b u t
voltage is very
low.
Software is
HYSECURITY
being loaded
LOADER
into Smart DC
Controller.
ALERT 1 FORCE
G a t e f o r c e d
OPEN
open.
ALERT 2
G a t e d r i f t e d
DRIFT CLOSED
closed.
G a t e d r i f t i n
ALERT 3 EXCESS
transit - Advisory
DRIFT
only
Thermal overload
alert. When alert
ALERT 4 MOTOR
is triggered, gate
OVERLOAD
can only "fully
open" until alert
is cleared.
ALERT 5 BOTH
Not used on
LIM ACTIVE
SlideSmart.
ALERT 6 LIM
Not used on
NOT RELEASED
SlideSmart.
H y 5 B
ALERT 7
d e t e c t e d
FREQ SHIFT
f r e q u e n c y
FAULT
change outside
normal range.
102
102
support.hysecurity.com
Table 16. Smart DC Controller - Troubleshooting
Description
Fault
Several possible causes:
• AC power has been shut off from
D C
the operator for too long and the
batteries are drained.
b a t t e r y
• Wiring problem.
• Batteries no longer hold a charge.
• Bad Smart DC Controller.
• Bad transformer.
Software is currently being loaded.
Gate has been forced open from a full
close limit and is being prevented from
re-closing.
Gate has drifted closed from a full
open limit and is being prevented from
re-opening.
Alert appears if gate drifts three times
in a five minute period.
Motor drive heat sink exceeds 195°F.
Alert will temporarily disable operator,
but will automatically reset itself when
it cools down. May also occur if the
heatsink temperature is 70°F. higher
than ambient temperature.
N/A
N/A
Likely causes are poor integrity of
h a s
loops or metallic objects within range.
a
This message will also indicate which
detector alert applies to: Exit Loop
(ELD), Inside Obstruction Loop (IOLD),
Outside Obstruction Loop (OOLD), or
Center Loop (CLD).
TROUBLESHOOTING
Possible Causes
Solutions
1. No AC Power. See
above item.
2. Wiring / Connector
problem - check
all connections.
Clean or repair as
required.
3. Check battery
condition.
Wait for software to finish
loading.
Will self-clear after an
open or close input.
Will self-clear after an
open or close input.
Check track to make sure
it is level.
Check gate hardware,
weight/length of gate.
Alert automatically clears
when temperature drops
below threshold.
N/A
N/A
Loop lead in wires and
ro a d w a y s h o u l d b e
checked for problems
or replaced.
Need help?
Do you have a question about the HySecurity SlideSmart DC Series and is the answer not in the manual?