Display
Alert, Error or
Condition
H y 5 B
ALERT 8
d e t e c t e d
LOOP SHORTED
loop shorted to
ground.
H y 5 B
ALERT 9
detected a lack
LOOP OPEN
of continuity in
loop wire.
Smart DC
Controller has
detected a
ALERT 10
communication
12C BUS ERROR
error with a
Hy5B vehicle
detector.
S m a r t
Controller has
ALERT 11
d e t e c t e d
DETECTOR
problem within
FAULT
an Hy5B vehicle
detector.
Smart DC
Controller has
an active loop
ALERT 12
input (Hy5B or
ON TOO LONG
box detector
output) for more
than 5 minutes.
S m a r t
Controller has
detected a gate
ALERT 13
that, over time,
STIFF GATE
has taken more
power to move
than it used to.
Table 16. Smart DC Controller - Troubleshooting
Description
Fault
h a s
a
Caused by inadequate insulation of
loop wires.
h a s
Caused by broken loop wire or wire
has come unplugged from detector.
Caused by removal of Hy5B or lack
of integrity of socket connection.
This message will also indicate which
detector alert applies to: Exit Loop
(ELD), Inside Obstruction Loop (IOLD),
Outside Obstruction Loop (OOLD), or
Center Loop (CLD).
D C
Caused by a fault within Hy5B. This
message will also indicate which
a
detector alert applies to: Exit Loop
(ELD), Inside Obstruction Loop (IOLD),
Outside Obstruction Loop (OOLD), or
Center Loop (CLD).
Caused when Smart DC Controller
sees an active loop for more than
5 minutes. "Active" loop can be
actual or false. This message will
also indicate which detector alert
applies to: Exit Loop (ELD), Inside
Obstruction Loop (IOLD), Outside
Obstruction Loop (OOLD), or Center
Loop (CLD).
D C
Caused by degrading gate hardware
or debris in track. This alert appears in
history log. It does not have any effect
with regard to opening or closing
gate. Caused when motor current is
too high.
TROUBLESHOOTING
Possible Causes
Solutions
Loop lead in wires and
ro a d w a y s h o u l d b e
checked for problems
or replaced.
Loop and lead in wires
should be checked for
problems or replaced.
Remove and re-install
the Hy5B and press
RESET. Replace Hy5B, if
necessary.
Remove and re-install
the Hy5A and press
RESET. Replace Hy5B, if
necessary.
Check traffic patterns
at site. Loop and lead
in wires should be
checked for problems
or replaced.
Check and correct gate
hardware as required.