REINSTATING FACTORY DEFAULTS
Eleven menu configurations are available in the
User Menu. Several other items in the Installer
Menu let you customize the operator depending
on the number of attached accessories and your
customer's needs.
CAUTION
Reinstating factory default clears ALL menu
settings stored in the operator and returns
them to factory defaults. It is recommended
that you save the menu settings before
reinstating factory defaults. You can write the
settings in a notebook or, if you have a laptop
computer, you can use HySecurity's START
software and download the menu settings and
save them to a file to upload to the operator
at a later date.
To reinstate factory defaults, take the following
steps and see Figure 53:
1. At a gate status display, press the MENU
button twice. This accesses the User Menu and
the CLOSE TIMER display appears.
2. Simultaneously, press the OPEN and RESET
buttons to enter the Installer Menu. Release
the buttons and the LEARN LIMITS display
appears. It is the first item in the Installer Menu.
3. Press NEXT until the FACTORY DEFAULTS
display appears. The factory default setting
is 0.
4. Use the SELECT and NEXT buttons to navigate
and change the number on the display to 1.
NOTICE
When you press SELECT to accept FD 1, the
factory settings are reinstated immediately and
the menu display returns to the initial Setup
Menu. The gate operator will not run until the
three menu parameters are entered: Usage
Class, Gate Handing, and Gate Weight along
with Sensor 1, 2, and 3. The limits will also
need to be relearned. Refer to "Programming
the Initial Setup Menu" on page 26 and
"Establishing the Open & Close Limits" on
page 28.
60
60
support.hysecurity.com
DISPLAY AND MENU OPTIONS
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
PREV
NEXT
SELECT
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
PREV
NEXT
SELECT
LL 0 (OFF)
LEARN LIMIT
CLOSE
OPEN
STOP
PREV
NEXT
SELECT
FD 1 (ON)
FACTORY DEFAULTS
OPEN
CLOSE
STOP
PREV
NEXT
SELECT
Figure 54. Reinstating Factory Defaults
1. Start at a gate
status display.
RESET
2. To access the
User Menu,
press the MENU
button twice.
MENU
RESET
3. Access the
Installer Menu, by
simultaneously,
pressing the
OPEN and
RESET
buttons.
MENU
RESET
4. Use NEXT to
navigate to the
FD menu display.
Change the
setting using the
SELECT and
NEXT buttons.
MENU
RESET
Need help?