Table 10. Smart DC Controller - Installer Menu Functions
Ref.
User Menu
No.
Display
IR 1 REVERSE
INSIDE OBS LOOP
30
DL 1 STANDARD
DETECTOR LOGIC
31
68
68
support.hysecurity.com
Setting Options
(Bold = Factory
Menu Tasks and Explanations
Settings)
Default is for full reversal when
0 = Pause closing
Inside Obstruction Loop is
only
triggered while closing. A setting
1 = Enable
of 0 causes gate to only pause
reversing to
when triggered. Closure begins
open
as soon as loop is clear again.
This selection determines
whether close timer begins
to count down after vehicles
have departed detector loops
or whether close timer will
count down while the loops are
occupied. Gate can only close
when all loop detectors are clear.
1 = Standard
Default settings causes Close
2 = Quick closed
Timer to start when all loops are
3 = Forced Time
clear. A setting of 2 causes Close
out
Timer to start when open limit
is reached. A setting of 3 forces
4 = Full anti-
the Close Timer to 0 when the
tailgate
OOLD and IOLD are tripped
simultaneously. A setting of 4
stops the gate when OOLD and
IOLD are tripped simultaneously
and closes from that point when
the loops clear.
DISPLAY AND MENU OPTIONS
DC Controller
Display
Connections
INSIDE OBS LOOP
COM or Hy5B
Hy5B