Site Overview & Planning
Be sure to place the
WARNING
WARNING signs on both
sides of the gate. For your records, take a
photograph of the completed installa�on site.
Attach WARNING Signs
Public Side
Maximum 2¼" (57mm)
width between
ver�cal bars
Edge sensor
on trailing
edge
Photo eye (entrapment protec�on shown in four loca�ons)
Physical stop - weld stops at both ends of V track
Operator
Duty Cycle
Power, 1Ø
Motor
Gate Speed
Gate Weight
Note: For SlideSmart DC Solar operators, refer to www.hysecurity.com
Edge sensor
Earth ground
Target magnet on chain
Figure 2. Site Overview and Planning
Table 1. SlideSmart Specifications
SlideSmart DC 15
Continuous
Switch Selectable
115 volts, 3 amps, 50/60 Hertz
208-230 volts, 1.5 amps, 50/60 Hertz
½ hp
0.75, 1 ft/s (23, 30, 38 m/s)
Maximum 1500 lbs (675 kg)
Key or Card reader
Mount access control
devices at least 6�
(183cm) beyond the gate.
Edge sensor on
leading edge
To comply with ASTM F2200, a screened wire
mesh extends to the top of the gate or to a mimimum
height of 6 �. (183cm) if a 2¼" (57mm) or larger gap exists
between the ver�cal bars.
SlideSmart
115 volts, 3 amps, 50/60 Hertz
208-230 volts, 1.5 amps, 50/60 Hertz
1.75, 2 , or 2.25 ft/s (53, 61, or, 69 cm/s)
Maximum 1000 lbs (450 kg)

INSTALLATION

Pedestrian gate.
Make sure a separate walk-
through entrance is available
and its pedestrian path is
clearly designated.
Photo eye
Physical
stop
V track
Secure Side
Site Overview
SlideSmart DC 10F
Continuous
Switch Selectable
½ hp
MX4505 Rev.H ©2022