Ref.
User Menu
No.
Display
LD 5
LCD CONTRAST
9
LG 0 (OFF)
VIEW EVENT LOG
10
DS 0 (OFF)
DIAGNOSTIC LOGS
11
Table Notes:
The following conditions apply to the indicated reference-numbered menu selections:
Table Note 1:
For gate operators using Type D entrapment protection, an automatic closing device (such as a
timer, loop sensor, or similar device) shall not be employed.
Table Note 2:
WARNING: Do NOT cut the wires to the buzzer or unplug it as the operator will not be in
compliance with UL 325. Failure to comply may result in serious injury or death.
54
54
support.hysecurity.com
Table 9. Smart DC Controller - User Menu Functions
Setting Options
(Bold = Factory
Settings)
5
0 through 9
0 = off
1 = on
0 = off
(standard)
1 = on (detailed)
DISPLAY AND MENU OPTIONS
Menu Tasks and Explanations
Under some extreme high or low
temperature conditions, it may be
necessary to adjust LCD contrast.
Display is adjustable from 0-9 with
a factory default setting of 5.
With v5.53 (or later) software,
you can set LG to 1 and view
abbreviated event logs on the
display. These messages are
helpful for diagnostic purposes
and reviewing the gate operator's
event history. Over 300 events can
be logged before the software
begins overwriting the existing
history.
Set this item to 1 to record all
gate operator open and close
events, in addition to normal
alert, fault and error logs. This
parameter automatically resets to
the default 0 (off ) after 24 hours,
which is useful when experiencing
intermittent problems. Set to 0,
DC Controller logs pertinent gate
operator events such as faults,
errors, or menu manipulation.
A setting of 1 bogs down the
processor so only use sporadically.
Associated
DC Controller
Connections
(N/A)
(N/A)
USB or
RS232 cable
and laptop
computer with
HySecurity's
free START
software is
required to
read the log
file.