Nice HySecurity SlideSmart DC Series Installation And Programming Manual page 108

Slide gate operator
Table of Contents

Advertisement

Display
Alert, Error or
Condition
Display provides
no indication of
this error, but it
can appear in
ERROR 5
START log and
No display
means that Smart
DC Controller
has detected a
serious internal
error.
ERROR 6
Not used in
STC-VFD
SlideSmart.
COMM ERR
Software issue
ERROR 7
exists that may
MENU
require factory
CHECKSUM
reset.
ERROR 8
RPM sensor
RPM SENSOR
disconnected.
S m a r t
ERROR 9
C o n t r o l l e r
BATTERY
detects no battery
DISCONNE
connected.
ERROR 10
Not used in
SLOWDOWN
SlideSmart.
SWITCH
108
108
support.hysecurity.com
Table 16. Smart DC Controller - Troubleshooting
Description
Fault
Internal software/hardware error.
Report any instance of this error to
HySecurity Technical Support.
N/A
Corrupt software or data.
Motor Encoder or wires are damaged
or unplugged.
Batteries are disconnected, or a wiring
D C
fault exists. SlideSmart operators ship
with a wire disconnected to prevent
battery drain. Replaced by Alert 28 in
h5.57 software version for AC powered
operators
N/A
TROUBLESHOOTING
Possible Causes
Solutions
1. Turn both switches
off to reset software.
2. Update to latest
software version
using START.
3. Replace Smart DC
Controller.
N/A
Call HySecurity Technical
Support for assistance.
Check wiring from motor
to Smart DC Controller
board.
1. Ensure red wire in
upper left corner
of control box is
connected to switch.
2. Correct any issues
with battery wiring.
3. Check 35 amp fuse
on circuit board.
N/A