Voltage monitors connected to power indicator LEDs monitor the regulated power on the
board (see
Figure
2-23). The indicator LEDs illuminate red if a regulated supply voltage is
out of spec, and illuminate green if the regulated supply voltage is nominal. Each
regulated supply voltage has a corresponding test point located near its indicator LED. See
the ML410 schematics and the associated data sheets for more information.
In addition to the voltage monitors, the ML410 employs a SMBus device, LM87, which
samples several of the same supply voltages when accessed over the System Management
Bus. See the
"IIC/SMBus Interface"
VCC1V2
TP17
1.2V
U5
LTC1326
VCC2V5
TP14
2.5V
U24
MC34161D
VCC3_PCI
TP10
3.0V
U18
MC34161D
VCC3V3
TP8
3.3V
U13
MC34161D
www.xilinx.com
section for more information.
VCC5V
VCC5V
TP16
5.0V
RED = Fault
GRN = Nominal
DS8
VCC5V
VTT_DDR2
TP13
0.9V
RED = Fault
`
GRN = Nominal
DS6
AVCCAUXMGT
VCC5V
TP9
2.5V
RED = Fault
GRN = Nominal
DS4
VCC1V8
VCC5V
TP7
1.8V
RED = Fault
GRN = Nominal
DS2
Figure 2-23: Voltage Monitors
ML410 Embedded Development Platform
VCC5V
U28
RED = Fault
GRN = Nominal
MC34161D
DS7
VCC5V
U23
RED = Fault
GRN = Nominal
NCP300
DS5
VCC5V
U17
RED = Fault
GRN = Nominal
MC34161D
DS3
VCC5V
U12
RED = Fault
GRN = Nominal
MC34161D
DS1
UG085_22_111505