Mitsubishi Electric MELSERVO MR-J2-A Product Specifications And Installation Manual page 61

Servo motors and servo amplifiers
Table of Contents

Advertisement

2. OPERATION
(2) Expansion parameters
To use the expansion parameters, change the setting of parameter No. 19 (parameter write
disable). After setting parameter No. 19, switch power off once, then switch it on again to make
the parameter valid.
The table below shows the parameters referenced and write enabled by the setting of param-
eter No. 19. Those parameters marked
Set Value
Operation
Reference
0000
(initial value)
Reference
000A
Reference
000B
Reference
000C
Basic Parameters
No.0~19
Write
Allowed for No. 19 only
Write
Allowed for No. 19 only
Write
Write
can be operated.
Expansion Parameters
No.20~49
2– 30

Advertisement

Table of Contents
loading

Table of Contents