2. OPERATION
(2) Output signal forced output
The output signal can be forced on/off independently of the servo status. This function is used
for output signal wiring check, etc. This operation must be performed in the servo off state
(SON signal off).
Operation
Call the display screen shown after power-on.
CN1A
CN1B
CN1B
14
18
4
Press MODE once.
Press UP twice.
Press SET for more than 2 seconds.
• • • • • • •
• • • • • • •
CN1B
CN1B
CN1A
CN1A
6
19
18
19
Press MODE once.
• • • • • • •
Press UP twice.
• • • • • • •
Press DOWN once.
• • • • • • •
Press SET for more than 2 seconds.
Switch on/off the signal below the lit segment.
Indicates the ON/OFF of the output signal. The correspondences
between segments and signals are as in the output signals of the
external I/O signal display.
(Lit: ON, extinguished: OFF)
The segment above CN1A-pin 18 is lit.
CN1A-pin 18 is switched on.
(CN1A-pin 18-SG conduct.)
CN1A-pin 18 is switched off.