Audi A3 1997 ➤
Heating, Air Conditioner - Edition 06.2000
Removing and installing.
-
Open flap -D- of the thermal insulation mat (at the pre-punched point) and remove condensation drain valve.
Notes:
◆ Remove condensation drain valve -A- from floor panel downward - ensure proper positioning in cross-panel
-B- when installing.
◆ The installed condensation drain valve must not make contact with the thermal insulation mat flap -D-.
◆ The condensation drain valve must not be gummed up with wax or underseal.
◆ -> In the event of complaints of moisture in passenger compartment, check condensation drain -C- is cor‐
rectly seated in condensation drain valve -A-.
5.4 - Removing and installing heat insulation for the expansion valve
-
-> Press together both shells -A- and -B- of the heat insulation until the catches engage.
Note:
If no heat insulation has been installed or if it has been improperly installed, the air conditioner capacity may
be adversely affected (pre-set regulatory curve change due to heat radiation).
162
87 - Air conditioning
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.