Audi A3 1997 Manual page 142

Hide thumbs Also See for A3 1997:
Table of Contents

Advertisement

Audi A3 1997 ➤
Heating, Air Conditioner - Edition 06.2000
Notes:
-
-> Jumper contacts 1 and 2 of connector -B- in order to check refrigeration capacity with switch removed.
-
The refrigerant circuit remains closed - connection with valve.
Check function.
-
Start engine
-
Compressor switched on (set "auto" mode on the operating and display unit).
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
-
Compressor is driven:
-
-> Detach connector -B- from switch.
-
Compressor stops (low pressure switch open).
-
Remove switch -A- and connect connector -B-.
-
Compressor is not switched on (low pressure switch open).
-
Compressor is not driven:
-
Detach connector -B- from switch -A- and jumper contacts 1 and 2 at connector -B- => compressor is
switched on.
Notes:
◆ If the compressor is switched on when jumpered, either the refrigerant circuit pressure is too low (refrigerant
circuit empty) or the switch is defective.
◆ To check the pressure in the refrigerant circuit, send the vehicle to an VW and Audi air-conditioning service
centre.
◆ If the compressor is not switched on and the switch -F129 is displayed as a compressor shutoff criterion in
the measured value block, locate and rectify the open circuit in the wiring between the switch -F129 and the
-E87 =>Page
46
.
136
87 - Air conditioning