Audi A3 1997 Manual page 112

Hide thumbs Also See for A3 1997:
Table of Contents

Advertisement

Audi A3 1997 ➤
Heating, Air Conditioner - Edition 06.2000
-
Carefully detach Bowden cable from lever arm.
Notes:
◆ Check the Bowden cables before fitting, replace stiff or damaged Bowden cables
◆ After installing the Bowden cables, turn the rotary control from end stop to end stop (both stops must be
reached).
Install and adjust Bowden cable on temperature flap
-
Turn rotary control for temperature flap to maximum setting for "cold".
-
-> Connect Bowden cable to lever arm for temperature flap -B-.
-
Push down slightly on lever arm -B- for temperature flap in direction of arrow.
-
Secure Bowden cable sheath with clip -A-.
-
Turn the rotary control for temperature flap from end stop to end stop (both stops must be reached).
Install and adjust Bowden cable on central flap and footwell/defroster flap
-
Turn rotary control for air distribution to end stop in the "Air to windscreen" position.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
-
-> Connect Bowden cable to lever arm for central flap -C-.
-
Push down slightly on lever arm -C- for central flap in direction of arrow.
-
Secure Bowden cable sheath with clip -A-.
-
Turn the rotary control for air distribution from end stop to end stop (both stops must be reached).