Audi A3 1997 Manual page 17

Hide thumbs Also See for A3 1997:
Table of Contents

Advertisement

V.A.G 1551 printer
00604
Potentiometer -G113 in positioning
motor -V71 (for air flow flap) 1)
* Short to earth/SP
* Open circuit/short to
positive /SP
* Adaptation limit exceeded 2)
1)
This positioning motor actuates the fresh/recirculated air flap in addition to the air flow flap.
2)
This fault is only detected during basic setting.
3)
Both end stops must be reached.
V.A.G 1551 printer
00606
Two-way valve for refrigerant shut-
off valve -N147 1)
*Short to earth/SP
*Open circuit/short to
positive /SP
1) The two-way valve -N147 is only installed in vehicles with map-controlled engine cooling and one operating
and display unit -E87 with one display.
V.A.G 1551 printer
00625
Vehicle speed signal
* Implausible signal /SP
00779 3133
Ambient temperature sensor -G17
*Short to earth/SP
*Open circuit/short to
positive /SP
Possible causes of fault
- Short circuit, open circuit in wiring
or fault in pin assignment of con‐
nectors between -G113 and -E87.
Air flow flap or fresh/recirculated air
flap stiff.
Potentiometer -G113 in -V71 defec‐
tive.
Possible causes of fault
▪ In the event of an-E87 with two
displays
Fault not intended
▪ In vehicles without map-controlled
engine cooling and one -E87 with
one display
Wrongly coded operating and dis‐
play unit -E87
▪ In vehicles with map-controlled en‐
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
gine cooling and one -E87 with one
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
display
with respect to the correctness of information in this document. Copyright by AUDI AG.
Wrongly coded operating and dis‐
play unit -E87
Short circuit or open circuit between
-N147 and -E87.
Two-way valve -N147 defective.
Possible causes of fault
- Loose contact in the wiring be‐
tween road speed sender -G68,
dash panel insert or another com‐
ponent also connected to this signal
(e.g. radio or cruise control unit) and
-E87.
Invalid signal from speedometer -
G21/dash panel insert, or another
connected component destroys the
signal.
- Short circuit or open circuit be‐
tween -G17 and -E87.
Temperature sensor -G17 defec‐
tive.
Heating, Air Conditioner - Edition 06.2000
- Use current flow diagram to locate
and eliminate short circuit, open cir‐
cuit in wiring or fault in pin assign‐
ment.
Check air flow valve and fresh/recir‐
culated air flap3) for ease of move‐
ment.
Replace positioning motor -V71.
Check and correct coding of -E87
(=> Page
Checking and correcting coding of -
E87 (=> Page
- Use current flow diagram to locate
and eliminate loose contact:
Check road speed signal from sender
-G21 or from the dash panel insert
(note all the components connected
to this signal wire).
=> Electrical System; Repair group
90
- Use current flow diagram to locate
and eliminate short circuit or open cir‐
cuit
Check temperature sensor -G17
(=>Electrical check, Page
Audi A3 1997 ➤
Fault remedy
Fault remedy
27
).
46
).
Fault remedy
46
).
4.1 - Fault table
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents