Audi A3 1997 Manual page 46

Hide thumbs Also See for A3 1997:
Table of Contents

Advertisement

Audi A3 1997 ➤
Heating, Air Conditioner - Edition 06.2000
Notes on display zone 1:
In the event of a faulty display, also check encoding of the operating and display unit -E87.
Display zone
▪ Footwell vent temperature sender -G192.
2
Measured value of sensor in °C(check=> Electrical test, Page
Operating and display unit -E87 with two displays
3
▪ Dash panel temperature sensor -G56.
Measured value of sensor in °C(check=> Electrical test, Page
Operating and display unit -E87 with one display
▪ Temperature sensor dash panel -G56 (installed in -E87).
Check temperature in front of the intake grille installed into -E87.
▪ Refrigerant temperature supplied from dash panel insert in °C
4
Auxiliary variable for control of fresh air blower speed.
Shut-off criterion exists for compressor if refrigerant temperature too high (check=> Electrical
check, Page
Note on display zones 2 and 3:
The measured value from a defective temperature sensor is suppressed by -E87, and -E87 then uses an internal
calculated value for the further control (the current measured value is displayed).
Notes on display zone 4:
◆ The signal is used by -E87 for control calculation starting at a refrigerant temperature of + 40 °C.
◆ In the absence of a signal, -53 °C (+ 125 °C only for software version D71) is displayed as the refrigerant
temperature, and the refrigerant temperature is calculated by -E87.
◆ If the refrigerant temperature from the dash panel insert is too high, the dash panel insert switches its output
to earth and 121 °C is displayed as refrigerant temperature and the compressor is switched off.
◆ The "refrigerant temperature" wiring from -E87 to the dash panel insert does not exist in all model year 1997
and 1998 vehicles.
=> Current Flow Diagrams, Electrical Fault-Finding and Fitting Locations
◆ For vehicles without "refrigerant temperature" wiring between -E87 and the dash panel insert, compressor
shutoff in the event of excessively high refrigerant temperature is actuated by refrigerant temperature switch
-F14.
=> Current Flow Diagrams, Electrical Fault-Finding and Fitting Locations
◆ For vehicles with pressure switch -F129 with "refrigerant temperature" wiring between -E87 and dash panel
insert, compressor shutoff in the event of excessively high refrigerant temperature is controlled by refrigerant
temperature switch -F14 or by the dash panel insert.
=> Current Flow Diagrams, Electrical Fault-Finding and Fitting Locations
Display group 008:
Voltage at fresh-air blower -V2, side lights, voltage at terminal 58d and 58s
Display zone
▪ Specified voltage for fresh air blower -V2 (calculated by -E87).
1
0 V to 12.5 V (depending on the -E87 setting).
▪ Actual voltage at fresh air blower -V2.
2
Deviation from the specified voltage (in the vehicle voltage range) less than 0.7 V.
40
01 - Self-diagnosis, Electrical check
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
46
).