Heating, Air Conditioner - Edition 06.2000
V.A.G 1551 printer
01272 4123
Central flap positioning motor -V70
* Blocked or de-energised /SP
V.A.G 1551 printer
01273 4124
Fresh air blower -V2
* Control difference /SP
01274 4131
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
Air flow flap positioning motor -V71 1)
with respect to the correctness of information in this document. Copyright by AUDI AG.
* Blocked or de-energised /SP
1)
This positioning motor actuates the fresh/recirculated air flap in addition to the air flow flap.
V.A.G 1551 printer
01296
Centre vent temperature sender -
G191
* Short to earth /SP
* Open circuit/short to
positive /SP
(cont.)
Note:
In vehicles with an operating and display unit -E87 up to index "E" no sender for the venting temperature -G191
is installed.
V.A.G 1551 printer
01296
Centre vent temperature sender -
G191
* Short to earth /SP
* Open circuit/short to
positive /SP
16
01 - Self-diagnosis, Electrical check
Possible causes of fault
- Short circuit, open circuit in wiring
or fault in pin assignment of con‐
nectors between -V70 and
-E87.
Central flap stiff.
Positioning motor -V70 defective
Possible causes of fault
- Short circuit or open circuit be‐
tween -V2, blower control unit -
J126 and/or -E87.
Open circuit in the power supply or
earth connection to -J126.
Control unit -J126 defective.
Fresh air blower -V2 defective.
- Short circuit, open circuit in wiring
or fault in pin assignment of con‐
nectors between -V71 and
-E87.
Air flow flap or fresh/recirculated air
flap stiff.
Positioning motor -V71 defective.
Possible causes of fault
Operating and display unit -E87 up to index "E" (two displays)
- Operating and display unit -E87
wrongly coded.
Short circuit to earth on connector
B, contact 6 to -E87.
Possible causes of fault
Operating and display unit -E87 with index "M" or "N" (two displays)
▪ Vehicles without map-controlled
cooling
Short circuit to earth on connector
B, contact 6 to -E87.
Operating and display unit -E87 in‐
correctly coded (sender -G191 is
not installed in Audi A3 without
map-controlled cooling).
Fault remedy
- Use current flow diagram to locate
and eliminate short circuit, open cir‐
cuit in wiring or fault in pin assign‐
ment.
Check freedom of movement of the
central flap.
Check positioning motor -V70 (=>
Final control diagnosis, Page
18
).
Fault remedy
- Use current flow diagram to locate
and eliminate short circuit or open
circuit
Use current flow diagram to locate
and eliminate the open circuit:
Check control unit -J126 (=> Elec‐
trical check, Page
46
Replace fresh air blower -V2.
- Use current flow diagram to locate
and eliminate short circuit, open cir‐
cuit in wiring or fault in pin assign‐
ment.
Check freedom of movement of air
flow flap and fresh/recirculated air
flap.
Check positioning motor -V71 (=>
Final control diagnosis, Page
18
).
Fault remedy
- Correct coding of operating and dis‐
play unit -E87 (Checking coding =>
Page
27
).
Use current flow diagram to locate
and eliminate short circuit
Fault remedy
Use current flow diagram to locate
and eliminate short circuit
Correctly code operating and display
unit -E87 (Checking coding => Page
27
).
).