◆ The "two-way valve -N147" is only installed into vehicles with map-controlled engine cooling.
Indicated on display
Fresh air blower -V2
Temperature sensor blower -V42
(with an operating and display unit
-E87 with one display)
1)
Check function of blower -V42, using for example, smoke test, (hold smoke source in front of the intake
frame installed into the operating and display unit).
Indicated on display
Temperature flap positioning mo‐
tor -V68
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Indicated on display
Central flap positioning motor -
V70
Footwell/defroster flap positioning
motor -V85
Heating, Air Conditioner - Edition 06.2000
Desired function
- Fresh air blower -V2 is actuated for
2 secs. at a time at 0 V, 3 V, 6 V, 9
V, 12 V, 15 V, 0 V, etc.
- Blower -V42 (for temperature sen‐
sor installed into -E87) is switched
on and off in 5 sec. Switching inter‐
vals on or off (smoke is sucked up
by blower) 1).
Desired function
- Positioning motor -V68 moves from
stop to stop (fresh air blower is oper‐
ating, air recirculation mode).
Air temperature from the vents
changes.
Desired function
- Positioning motor -V70 moves from
stop to stop (fresh air blower operat‐
ing, air recirculation mode, tempera‐
ture flap set to "cold").
Air distribution switches between foot‐
well and dash panel vents.
- Positioning motor -V85 moves from
stop to stop (fresh air blower operat‐
ing, air recirculation mode, tempera‐
ture flap set to "cold").
Air distribution switches between foot‐
well and defrost.
Audi A3 1997 ➤
Fault remedy
- Check freedom of movement of the
fresh air blower.
Use current flow diagram to check the
earth connection to fresh air blower
control unit -J126.
Check control unit -J126 (=> Electri‐
cal check, Page
46
).
Renew operating and display unit -
E87.
- Check intake frame and intake hose
for blockage (=>Page
184
Renew operating and display unit -
E87.
Fault remedy
- Check wiring between -V68 and -
E87 for open circuit or incorrect in‐
stallation according to current flow
diagram.
Check freedom of movement of the
temperature flap.
Check positioning motor -V68 (=>
Electrical check, Page
Renew operating and display unit -
E87.
Fault remedy
- Check wiring between -V70 and -
E87 for open circuit or incorrect in‐
stallation according to current flow
diagram.
Check freedom of movement of the
central flap.
Check positioning motor -V71 (=>
Electrical check, Page
Renew operating and display unit -
E87.
- Check wiring between -V85 and -
E87 for open circuit or incorrect in‐
stallation according to current flow
diagram.
Check freedom of movement of
footwell/defroster flap.
Check positioning motor -V85 (=>
Electrical check, Page
Renew operating and display unit -
E87.