Display Groups 007 To 012 - Audi A3 1997 Manual

Hide thumbs Also See for A3 1997:
Table of Contents

Advertisement

Display zone
▪ Temperature sensor for fresh air intake duct -G89.
2
Measured value of sensor in °C(check=> Electrical test, Page
▪ Ambient temperature sensor -G17
3
Measured value of sensor in °C(check =>Electrical test, Page
▪ Sunlight penetration photosensor -G107.
4
0%to 100 %(corresponds to 4.5 V and 0.5 V )depending on sunlight penetration intensity.
Notes (display zones 1, 2 and 3):
◆ The basis for the display in display zone 1 is the lower of the two measured ambient temperatures (=>Display
zones 2 and 3). When the ignition is switched off, the value is stored up to 4 hours.
◆ The measured value from a defective temperature sensor is suppressed by -E87, and -E87 then uses an
internal calculated value for the further control.
Notes on display zone 4:
◆ The display value for photosensor -G107 may be changed by shining an appropriate bulb at the sensor.
◆ If, irrespective of the light conditions for photosensor -G107, the display always shows about 90 % or approx.
1V of the maximum sunlight penetration, use the current flow diagram to check the cabling to photosensor
-G107 for interchanges.

9.3 - Display groups 007 to 012

Display group 007:
Sender for venting temperature -G191 and -G192, temperature sensor dash panel -G56 and calculated refrig‐
erant temperature
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Display zone
Vehicles with an operating and display unit -E87 with two displays but without map-controlled
1
engine cooling.
▪ Display zone not used.
Ignore display, no venting temperature sender in centre of -G191 is installed into Audi A3 without
map-controlled cooling and in this model of the -E87.
Vehicles with an operating and display unit -E87 and two displays (indices "M" or "N") and with
map-controlled engine cooling (in vehicles with 1.6 l engine, gradual introduction as of model
year 1999).
▪ Centre vent temperature sender -G191.
Measured value of sensor in °C(check=> Electrical test, Page
Display zone
1
Vehicles with an operating and display unit -E87 with one display and map-controlled engine
(cont.)
cooling.
▪ Centre vent temperature sender -G191.
Measured value of sensor in °C(check=> Electrical test, Page
Vehicles with an operating and display unit -E87 with one display and without map-controlled
engine cooling.
▪ Centre vent temperature sender -G191.
Ignore display, centre vent temperature sender -G191 not installed in Audi A3 without map-
controlled cooling at the moment.
Check connectors to -E87 for short circuit (connector which is intended for the -G191=> Electrical
test, Page
46
).
Heating, Air Conditioner - Edition 06.2000
Display
Display
Display
Audi A3 1997 ➤
46
).
46
).
46
).
46
).