Audi A3 1997 Manual page 44

Hide thumbs Also See for A3 1997:
Table of Contents

Advertisement

Audi A3 1997 ➤
Heating, Air Conditioner - Edition 06.2000
Display group 004:
Footwell/defroster flap positioning motor -V85
Display zone
1
▪ Actual feedback value of potentiometer -G114 (in positioning motor -V85).
Display value greater than 5 and less than 250
Maximum permissible deviation: 3 units greater or less than the specified feedback value (only
in the range greater than 50 but less than 190)
▪ Specified feedback value of potentiometer -G114 (calculated by -E87).
2
Display range: 5 to 250
▪ -G114 value determined during the "basic setting" and stored in -E87 with the positioning motor
3
in the setting "Lower stop" (the footwell/defroster flap routes the air flow to the dash panel de‐
froster vents).
Display value greater than 5 and less than 50
▪ -G114 value determined during the "basic setting" and stored in -E87 with the positioning motor
4
in the setting "Upper stop" (the footwell/defroster flap routes the air flow to the vents in the foot‐
well).
Display value greater than 190 and less than 250
Note:
In the event of deviations from specified values, observe notes on display group 02 (see Page
Display group 005:
Air flow flap positioning motor -V71
Display zone
1
▪ Actual feedback value of potentiometer -G113 (in positioning motor -V71).
Display value greater than 5 and less than 250
Maximum permissible deviation: 3 units greater or less than the specified feedback value (only
in the range greater than 50 but less than 210)
2
▪ Specified feedback value of potentiometer -G113 (calculated by -E87).
Display range: 5 to 250.
▪ -G113 value determined during the "basic setting" and stored in -E87 with the positioning motor
3
set to "lower stop" (the air flow flap in the evaporator intake area is closed and the air conditioner
is in recirculated air mode).
Display value greater than 5 and less than 30
4
▪ -G113 value determined during the "basic setting" and stored in -E87 with the positioning motor
set to "upper stop" (the air flow flap in the evaporator intake area is open and the air conditioner
is in fresh air mode).
Display value greater than 210 and less than 250
Note:
In the event of deviations from specified values, observe notes on display group 02 (see Page
Display group 006:
Calculated outside temperature for external temperature display -G106, measured values for fresh air intake
duct temperature sensor -G89, outside temperature sensor -G17 and sunlight penetration photo sensor -G107
Display zone
▪ Calculated ambient temperature in °C.
1
for ambient temperature display -G106 in dash panel insert
38
01 - Self-diagnosis, Electrical check
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Display
Display
Display
37
).
37
).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents