Display group no. Display zone
Note:
The display groups "011" and "012" are only present in operating and display units with the Part Number 8L0
820 043 and the indices "H", "J", "K", "L" and from index "O" onwards (model with one display).

9.2 - Display groups 001 to 006

Display group 001:
Compressor shut-off conditions, voltage for magnetic clutch, at terminal "15" and signal for period "ignition off"
Notes:
◆ If one of the compressor shut-off criteria 1, 8, 11 or 12 exists, the magnetic clutch -N25 cannot be actuated
during the final control diagnosis (=>Page
◆ If compressor shutoff criterion "5" appears in addition to another compressor shutoff condition, disregard
shutoff criterion "5".
◆ If several compressor shutoff conditions exist simultaneously (display zone 1), the display will either show
them all alternately or it will show only the shutoff condition assigned the highest priority by operating and
display unit -E87.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
◆ If pressure switch -F129 is open, compressor shutoff criterion "1" (overpressure) first appears and then the
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
compressor is switched off. If pressure switch -F129 remains open for more than 30 secs., the program
with respect to the correctness of information in this document. Copyright by AUDI AG.
switches to compressor shutoff criterion "3" (vacuum, refrigerant circuit empty).
◆ High-pressure sensor -G65 will gradually replace air conditioner pressure switch -F129 (as of model year
1999, initially vehicles with 1.6 l engines). As of model year 2001 only high-pressure switches -G65 are
installed.
◆ For vehicles with high-pressure sensor -G65, radiator fan control unit -J293 calculates the refrigerant circuit
pressure and relays no more positive signals to -E87 if the pressure is NOK.
Display zone
1
Code Compressor shutoff criteria:
0
Compressor switched on:
▪ No shut-off criterion identified (if compressor is not switched on, perform Final control
diagnosis => Page
1
Compressor switched off (in vehicles with pressure switch -F129):
▪ Open pressure switch -F129 (between contacts 2 and 1) (overpressure or loose contact
in the wiring).
Fault remedy =>Fault table, Page
Compressor switched off (in vehicles with high-pressure sensor -G65):
▪ No positive signal from radiator fan control unit -J293 (refrigerant circuit pressure NOK
or fault in wiring, in -J293 or in -G65).
Fault remedy =>Fault table, Page
2
Vacant
Display zone
1
Code Compressor shutoff criteria:
3
Compressor switched off (in vehicles with pressure switch -F129):
▪ Open pressure switch -F129 (between contacts 2 and 1) (overpressure, empty refrig‐
erant circuit or open circuit).
Fault remedy =>Fault table, Page
34
01 - Self-diagnosis, Electrical check
4
Assignment of ignition key
18
46
).
Designation
)
Display
46
.
46
.
Display
46
.
Details on page