V.A.G 1551 printer
01044
Control unit incorrectly encoded
V.A.G 1551 printer
01087
Basic setting not performed
01206
Signal for ignition off time 1)
* Implausible signal /SP
1)
If, when the ignition is switched on, no "ignition off time" signal is detected by the operating and display
unit -E87(transmitted by the dash panel insert), the -E87 assumes a standing time of more than 4 hours and it
is assumed that the engine temperature is the same as the ambient temperature. In heating mode, the fresh
air blower may thus have a delayed start despite the engine being warm. Ambient temperature indicator -G106
in the dash panel insert may also display incorrect ambient temperature values.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
V.A.G 1551 printer
with respect to the correctness of information in this document. Copyright by AUDI AG.
01271 4122
Temperature flap positioning motor -
V68
* Blocked or de-energised /SP
Heating, Air Conditioner - Edition 06.2000
Possible causes of fault
▪ Vehicles without map-controlled
cooling
Proper encoding procedure for -E87
was not followed
Wrong code was entered
The -E87 is coded for a vehicle with‐
out map-controlled cooling and a re‐
sistance smaller than 100 kilo-ohms
is measured at the inlet for sender -
G191 (connector B, contact 6).
▪ Vehicles with map-controlled cod‐
ing
Proper encoding procedure for -E87
was not followed
Operating and display unit -E87 as of index "H" except index "M" or "N" (one
display)
- Proper encoding procedure for -E87
was not followed
Wrong code was entered
Possible causes of fault
- Either a fault occurred during the "ba‐
sic setting" function, or the ignition was
switched off and -E87 was not able to
complete the function.
When -E87 was replaced, no basic set‐
ting was performed.
The basic setting was performed on an
-E87 that was incorrectly encoded or
not encoded at all
- Open circuit or short in wiring between
dash panel insert and -E87.
Dash panel insert defective.
Possible causes of fault
- Short circuit, open circuit in wiring
or fault in pin assignment of con‐
nectors between -V85 and
-E87.
Temperature flap stiff.
Positioning motor -V85 defective.
Audi A3 1997 ➤
Fault remedy
Code operating and display unit -E87
as specified =>Page
Determining and rectifying short circuit
to contact 6 in connector -B- to -E87
Code operating and display unit -E87
as specified =>Page
- Code operating and display unit -E87
as specified =>Page
Fault remedy
- Check the coding of operating and dis‐
play unit -E87 =>Page
- Use current flow diagram to locate and
eliminate short circuit, open circuit in
wiring or fault in pin assignment.
Checksignal from dash panel insert (=>
Reading measured value block, Page
31
).
Fault remedy
- Use current flow diagram to locate
and eliminate short circuit, open cir‐
cuit in wiring or fault in pin assign‐
ment.
Check freedom of movement of the
temperature flap.
Check positioning motor -V68 (=>
Final control diagnosis, Page
18
).
4.1 - Fault table
27
27
27
24
15