Test step
Contact at
connector
to -J293
3.5
Connector
A contact 8
and
connector
A, contact 6
Test step 4 (signal from high-pressure sensor -G65)
Vehicle diagnosis system VAS 5051 (or commercially available oscilloscope)
"DSO" (digital storage oscilloscope) measurement system
Setting 2V/Div =, 5ms/Div (2 V DC and 5 milliseconds per unit)
Test step
Contact at
connector to
-J293
4.0
Connector A
contact 2
(signal)
and
connector A,
contact 6
(earth)
Vehicle diagnosis system VAS 5051 (or commercially available oscilloscope)
"DSO" (digital storage oscilloscope) measurement system
Setting 2V/Div =, 5ms/Div (2 V DC and 5 milliseconds per unit)
Test step
Contact at con‐
nector to -J293
4.0
(cont.)
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Notes:
◆ The signal from high-pressure sensor -G65 depends on pressure in refrigerant circuit => Page
Testing of
▪ Test conditions
- Additional opera‐
tions
"Compressor ON"
▪ Engine running
signal from -E87
▪ Operating and dis‐
play unit -E87 in "au‐
to" mode (compres‐
sor on)
Testing of
▪ Test conditions
- Additional oper‐
ations
Pressure-dependent
▪ Ignition on.
square-wave signal
from sender -G65
Testing of ▪ Test conditions
- Additional operations
11.3 - Electrical check at control unit -J293 (version for High-pressure sensor -G65)
Heating, Air Conditioner - Edition 06.2000
Specified value
- approx. battery
voltage
Specified value
- Square-wave signal
(dependent on pres‐
sure in refrigerant cir‐
cuit =>Page
Specified value Remedies if specified value
Audi A3 1997 ➤
Remedies if speci‐
fied value not at‐
tained
- Use current flow di‐
agram to locate and
eliminate open cir‐
cuit or short to posi‐
tive or earth in the
wiring between -
J293 and -E87.
Eliminate cause of
compressor shutoff
condition
Remedies if speci‐
fied value not at‐
tained
- Use current flow
diagram to check
voltage supply and
85
earth connections
to High-pressure
sensor -G65.
Use current flow di‐
agram to locate and
eliminate open cir‐
cuit in the wiring be‐
tween High-pres‐
sure sensor -G65
and control unit -
J293.
(cont.)
not attained
- Use circuit flow diagram to
locate and rectify short cir‐
cuit in the wiring from -G65
to -J293 or to the engine
control unit.
High-pressure sensor -G65
defective - replace.