Dynamic Nozzle Test - Stratasys J826 User Manual

3d printing system
Hide thumbs Also See for J826:
Table of Contents

Advertisement

Stratasys J826 User Guide

Dynamic Nozzle Test

Perform the Dynamic Nozzle Test if you suspect that poor quality in 3D prints is
caused by clogged or faulty nozzles in the print heads—even if this is not
indicated by the Pattern Test.
The Dynamic Nozzle Test prints eight (8) samples on the build tray, which you
can then visually inspect. Printing the samples takes about 20 minutes.
To run the Dynamic Nozzle Test:
1. Make sure that the build tray is clear (empty).
2. From the Options menu, select Dynamic Nozzle Test, and then select the
3. When the samples are printed, check if they have visible gaps.
DOC-28000 Rev. I
appropriate test for the current printing mode.
Figure 4-187 Selecting Dynamic Nozzle Test from the Options menu
............
Figure 4-188 Dynamic Nozzle Test samples
❒ In the left sample shown above, there are no gaps.
❒ In the right sample shown above, there are only two gaps, which is
acceptable.
Many gaps in the sample indicates that many nozzles in the print head are
not functioning. This might indicate the need to replace the defective head.
In this case, consult with your Stratasys service provider.
4 Operating and Maintaining the Printer
4-123

Advertisement

Table of Contents
loading

Table of Contents