13. Use the UV lamp clamp to insert the lamp bulb into place in the UV
14. Using a 2.5-mm hex key, secure the clamp to the UV reflector, and continue
15. Inspect the new UV reflector, and make sure that a black strip is attached to
16. Discard the old UV reflector and lamp.
Dispose of the used UV lamp in accordance with environmental and safety
requirements.
DOC-28000 Rev. I
reflector.
Figure 4-161 Pushing the UV lamp bulb into place
with step
.
17
Figure 4-162 Attaching the UV lamp clamp
the inside of it. If not, install one—on the side of the reflector opposite (not
next to) the print block.
Note: Extra black strips are included in the printer Start-Up Kit. If
necessary, you can remove the black strip from the old reflector and install it
in the new reflector (as long as the black paint has not faded).