Dynamic
Perform the Dynamic Nozzle Test if you suspect that poor quality in printed 
Nozzle Test
models is caused by clogged or faulty nozzles in the print heads—even if this 
is not indicated by the Pattern Test. 
The Dynamic Nozzle Test prints eight (8) samples on the build tray, which 
you can then visually inspect. Printing the samples takes about 20 minutes.
To run the Dynamic Nozzle Test:
1.  Make sure that the build tray is clear (empty).
2.  From the Options menu, select Dynamic Nozzle Test, and then select the 
3.  When the samples are printed, check if they have visible gaps.
Samples printed from certain Model materials in this test might not be
completely cured. Because some of the material remains in liquid (or semi-
liquid) state, you cannot check for gaps in these samples. Do not be
concerned that liquid resin remains on and around these samples.
DOC-28000 Rev. D
appropriate test for the current printing mode.
Figure 4-159 Selecting Dynamic Nozzle Test from the Options menu
............
Figure 4-160 Dynamic Nozzle Test samples
❒  In the left sample shown above, there are no gaps. 
❒  In the right sample shown above, there are only two gaps, which is 
acceptable. 
Many gaps in the sample indicates that many nozzles in the print head are 
not functioning. This might indicate the need to replace the defective 
head. In this case, consult with your Stratasys service provider.