Stratasys J826 User Manual page 127

3d printing system
Hide thumbs Also See for J826:
Table of Contents

Advertisement

Stratasys J826 User Guide
21. Return the holder (with the new tube) to the pump assembly, making sure
22. Close the latch on the pump to secure the tube holder.
23. Connect the new pump tube.
If necessary, replace the pump tube on the other waste pump.
24. Attach the clamp that secures the pump tubes on the housing (see Figure
25. Before returning the pump housing to the printer, check that the pump tube
26. Install the pump housing in the printer (see Figure 4-135 on page 4-93),
DOC-28000 Rev. I
that the clamp is on the side of the pump marked SUCTION.
Figure 4-143 Installing the new tube
Important: Make sure that the tube holder is secured by the latch on both
sides, as shown.
Figure 4-144 Tube holder secured in the pump
Make sure that you connect the suction tube from the printer to the correct
side of the pump tube.
4-138 on page 4-95).
is securely coupled to the tubes from the printer and that the tube holder is
securely locked in place.
making sure not to pinch or damage the tubes.
4 Operating and Maintaining the Printer
4-97

Advertisement